Eagle Microsystems EI-2000 User Manual
Page 9

P030 Tare lock enable (Y) or disable (N).
This applies to operational modes 1 & 4. While viewing the tare value, press and hold the up
or down arrow pushbutton. After three seconds, the tare value will be adjustable. Also, the
tare LED will flash. Press the select pushbutton to view the remaining weight and to store the
tare value permanently.
SCALE PARAMETERS
P100 through P400 set needed parameters for the attached scale bases. If a scale base is
set to OFF, this applies to channels 2, 3 and 4; all of its parameters are hidden except for the
scale selection.
P100-P199
Scale 1 parameters
P200-P299
Scale 2 parameters
P300-P399
Scale 3 parameters (EI-2000-EXP must be installed)
P400-P499
Scale 4 parameters (EI-2000-EXP must be installed)
P100 Scale selection (auto-configuration)
This parameter selects the Eagle Microsystems scale connected to the scale channel input
Px00 Function
OFF
This turns the channel off if it’s not needed (2, 3 and 4).
CY-1
Copy the channel 1 setup; this is available for channels 2, 3, and 4. The parameters
and set points are hidden since they are identical to channel 1.
USER All scale parameters are available.
1 & up
This selects a scale, see scale selection table below. All parameters are
automatically setup. The resolution and average parameters (Px11 & Px12) can be
changed.
SCALE SELECTION TABLE
Px00 Px10
Px11
Px12
Px13
Px16
Px17
Select
Scale type
F.S.
Res.
AZ
PTZ/AZ
range
Threshold
weight
Start
weight
lb/kg
lb/kg
%
%
lb/kg
lb/kg
1 DCS302 300/140
0.5/0.2
1% 2% 60/27.2 150/136
2 EDS400 400/180
0.5/0.2
1% 2% 60/27.2 150/136
3 DS750 750/340
0.5/0.2
1% 2% 60/27.2 150/136
4 WT3600
(1/ch)
4000/1810
5/2 1% 10% 1000/454 2000/907
5 WT3600
(2/ch)
8000/3630
5/2 1% 10% 1000/454 4000/1816
6 LP4300
/4000lb.
2000/910
1/0.5 1% 2%
50/23 2000/910
7 LP4300/12000lb.
6000/2720
1/0.5 1% 2%
50/23 6000/2720
8 ECS150x 300/140
0.5/0.2
1%
2%
60/27.2 150.0/68.0
9 WP1000
(300lb) 300/140
0.5/0.2
1% 2%
60/27.2 150.0/68.0
10 *WT3600
(1/ch)
4190/1900
5/2 1% 10% 1000/454 2030/920
11 *WT3600
(2/ch)
8380/3800
5/2 1% 10% 1000/454 4060/1840
12 WP1000
(600lb) 600/280
0.5/0.2
1% 2%
120/54.4 150.0/68.0
13 WP1000
(1200lb) 1200/560
0.5/0.2
1%
2%
240/108.8 150.0/68.0
*Australian typical load settings.