Noise gate, User’s guide – Drawmer Advanced Dynamics for Mackie D8B User Manual
Page 13
13
User’s Guide
Noise Gate
The ADX-100 Noise Gate with variable threshold level is
extremely effective in reducing background hiss and noise
during portions of a program with no signal. The ADX-100 also
has unique High-Pass/Low-Pass key filters, comprehensive
envelope control, and ultra-fast attack time. The gate works by
muting the corresponding channel when no signal is present, or
when the signal level falls below the gate threshold detection
level. Normally the gate level will be set below the lowest
program level so that it will pass all program material.
Input Signal
Noise Floor
Time
Gate
Threshold
Level
Audio Signal
Time
Lev
el
Lev
el
Audio Signal
Muted Signal
Output Signal
Key Listen
Button
Threshold
Slider &
Meter
Gate/Duck
Toggle
High/Low
Frequency Key
Filters
Mode Toggle
(Noise Gate/
Expander)
Active
Button
(fonts
are white
when en-
abled)
Trigger Button
(L&R Channel,
R Channel or L
Channel.
Attack
Slider
Hold
Slider
Decay
Slider
Range
Slider
Gate/Duck
Indicators