beautypg.com

96k 24bit recording and replay, D=fjah, Operation – Drawmer DC2496 High Resolution A/D Converter User Manual

Page 12: 96k 24 bit a/d input recording, 96k 24 bit a/d input replay from adat

background image

12

OPERATION

COMMENTS

INPUT

SIGNAL

OPERATION

FRONT PANEL

LIMITER

WORD

RESOLUTION

DITHER

SAMPLE

RATE

EXTENDED

WORK CLOCK

REPLAY

TRACK

MODE

DIGITAL

GAIN

EXT >

SPDIF

AES

TDIF

A/D

ADAT

HOLD

FAST

MED

OFF

SLOW

16 BIT

18 BIT

20 BIT

24 BIT

22 BIT

OFF

WHITE

DUAL

H.F.

M.F.

44.1K

48K

96K

88.2K

7,8

5,6

1,2

3,4

PLAY

RECO RD

0

+18

+6

+3

+9

+12

+15

AES/SPDIF

BNC

TDIF

ADAT

EXT >

SPDIF

AES

TDIF

A/D

ADAT

HOLD

FAST

MED

OFF

SLOW

16 BIT

18 BIT

20 BIT

24 BIT

22 BIT

OFF

WHITE

DUAL

H.F.

M.F.

44.1K

48K

96K

88.2K

7,8

5,6

1,2

3,4

PLAY

RECO RD

0

+18

+6

+3

+9

+12

+15

AES/SPDIF

BNC

TDIF

ADAT

EXT >

SPDIF

AES

TDIF

A/D

ADAT

HOLD

FAST

MED

OFF

SLOW

16 BIT

18 BIT

20 BIT

24 BIT

22 BIT

OFF

WHITE

DUAL

H.F.

M.F.

44.1K

48K

96K

88.2K

7,8

5,6

1,2

3,4

PLAY

RECO RD

0

+18

+6

+3

+9

+12

+15

AES/SPDIF

BNC

TDIF

ADAT

EXT >

SPDIF

AES

TDIF

A/D

ADAT

HOLD

FAST

MED

OFF

SLOW

16 BIT

18 BIT

20 BIT

24 BIT

22 BIT

OFF

WHITE

DUAL

H.F.

M.F.

44.1K

48K

96K

88.2K

7,8

5,6

1,2

3,4

PLAY

RECO RD

0

+18

+6

+3

+9

+12

+15

AES/SPDIF

BNC

TDIF

ADAT

96K 24Bit Recording and Replay

96K 24 Bit A/D Input Recording

Record a stereo signal as hex (6) tracks 1,2,3,4,5,6 on an

ADAT or Tascam 16/20Bit digital multi-track tape

recorder - and 7,8 stereo pair as 48K backup if required.

ADAT machines must be set to EXT Clock.

Tascam machines must be set to WORD clock.

and a BNC lead from DC2496 main word clock to

Tascam Word Clock in.

XLR balanced

inputs.

Use as

required

24 bit

bit splitting mode

to record

6 tracks

High Frequency

Noise shaped

dither

96K internal

sample rate

none

none

SELECT THIS

RECORD

LED FIRST

0 dB

If gain is applied

limiter

must be used

96K 24 Bit A/D Input

Replay from ADAT

Replay hex (6) tracks 1,2,3,4,5,6,

or 7,8 48K stereo pair.

ADAT must be set to INT Clock.

Light Pipe ADAT

optical in

Use as

required

24 bit

stereo mode

High Frequency

Noise shaped

dither

96K or 88.2K lit

whenhex

trackrecording is

replayed

ADAT external

optical input word

clock

Lit when hex track

recording is

replayed

SELECT THIS

PLAY

LED FIRST

6 dB

of gain with limit

use as required

96K 24 Bit A/D Input Replay

from TDIF i.e. DA-88

Replay hex (6) tracks 1,2,3,4,5,6,

or 7,8 48K stereo pair.

Tascam machines must be set to INT clock.

96K 24 Bit Replay from Hard Disk

recorder or other AES Digital Input

Monitor on D/A whilst recording to mini-disc,

ADAT and TDIF similtaneously

(All recording devices must use

external word clock)

96K 24Bit A/D conversion with monitor speakers recording and replaying, 8 Track

digital tape recorders, DAT and 24Bit 96K hard disk recorder, also recording 44.1K 16 Bit to
Mini-disc, all simultaneously.

Ensure that the A/D input signal does not light
the overload leds - analogue clipping will occur.
Reduce the mixer output level as required. Apply
DC2496 digital gain with limiter to allow more A/
D input headroom whilst preserving 0dBFS
digital level.

If the peak noise level from the mixing desk is
above -100dB then the bottom leds of the meter
will remain lit.

If the mixer has a -10dBu output level then the
analogue input switch should be pressed (+4dBu
max input signal level).

To ensure a 0dBFS digital signal level add a few
dB’s of digital gain and set the limiter to fast.

If digital gain is applied with the limiter off then
unpleasant digital distortion can occur on peaks.

When the DC2496 is running at 96K or 88.2K
and the main digital output is connected to a
48K digital input no signal will be received!

The A/D noise floor is 6dB higher at 96/88.2K
that at 48/44.1K.

When recording hex (6) tracks, tracks 7 and 8
will only monitor at 16Bit resolution from the
Sample Rate Converter (upper) digital outputs.

When the TDIF plug is inserted into the rear of
the DC2496 the main digital output word clock
BNC socket will be at 44.1K when recording at
88.2K and 48K when recording at 96K - and only
suitable for TDIF word sync input.

Always reduce monitor volume when selecting
different word clocks or sample rates.

ADAT and TDIF recordings will always be at
44.1/48K when recording 88.2/96K A/D or digital
input signals.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

TDIF digital

input fron

25 pin D plug

Use as

required

24 bit

stereo mode

High Frequency

Noise shaped

dither

96K or 88.2K lit

whenhex

trackrecording is

replayed

TDIF external
25 pin D plug

word clock

Lit when hex track

recording is

replayed

SELECT THIS

PLAY

LED FIRST

6 dB

of gain with limit

use as required

AES (XLR)

digital input

Use as

required

24 bit

stereo mode

High Frequency

Noise shaped

dither

96K or 88.2K lit

depending on

replay sample

rate

AES (XLR)
word clock

Not

Active

SELECT THIS

PLAY

LED FIRST

6 dB

of gain with limit

use as required

+D=FJAH

3

OPERATION