9

7/8

When the 7/8 switch is active the M-Clock can output at the Superclock standard, as
used by Pro Tools™.
The 7/8 switch affects only connectors 7 and 8 on the BNC Clock Outputs on the rear of the
panel, working independantly from the other outputs.

Output Sample Rate

7/8 Switched IN (Superclock)

44.1 kHz

11.2896 mHz

48 kHz

12.288 mHz

88.2 kHz

11.2896 mHz

96 kHz

12.288 mHz