Crane Song AVOCET II User Manual
Page 53

Avocet alignment
The alignment should not be changed unless you are 100 % positive that you know how to do this
and have very good equipment. If not you could mess up the alignment, and the left - right channel
balance. The gain trims will provide a plus or minus 3 db range, which can allow for different configu-
rations. Do not attempt to adjust this as a way to reduce the output level. If you do you will mess it
up. If you need to reduce the output level use the provided pads. There is 5 db of analog headroom
above the zero or red led on the remote’s meter.
If the rom has surround frimware set it to stereo operation before power up
Jumper JP1 must be installed on power up
This jumper should not be changed with out power down and power up
With Att at max level, 1khz sine wave
Put the signal into analog 1 and mono the unit
adjust the generator for 1.000V at the (
MONO TEST POINT IC7 PIN 1
)
ch1 and ch2 should be equal
R166, R167 are the gain trims
(CHANNEL GAIN MATCHING)
adjust the output for 1.783 volts in both channels
use 5.1k ohm load on the output, measure the output balanced
turn mono off
ANALOG INPUT TRIMS
1.000v in = 1.000v out
adjust the trims for ANA1, ANA2, and AUX inputs they can be reached by small holes next to the xlr
connectors on the back
DIGITAL INPUT TRIMS
select DAW feed a 1khz sine wave at digital full scale
gain Att. still at max
adjust for 7.70 volts output this is 20db above 0dbm
Jumpers to select input level metering should be installed
REMOTE METER ADJUST with max digital input adjust the meter trims for meter full scale
(R165, R166)
DIGITAL METER OUTPUT WITH ANALOG INPUT
Apply an 1KHz analog input and adjust it for 7.70 volts out with the att. at max
(this is the same level as digital zero on the digital input)
With a digital meter connected to the metering output adjust the meter level trims for digital zero
53
53
53