Sloped Ceiling Installations

When to Use an Extension Downrod
For optimum performance and appearance, use
an extension downrod with your Casablanca
fan when installing on high (cathedral) ceilings
or sloped ceilings. Casablanca offers accessory
downrods in increments of 6" up to 5’. See your
Authorized Casablanca Dealer for details.

Calculation of Ceiling Angle
Use the tear-off Ceiling Angle Template card inserted
in this manual. It provides you with a simple “go” or
“no go” for installing your fan on a sloped ceiling.

NOTE:

The fan may wobble or vibrate if the

downrod length is not long enough and the
inside blade is too close to the downslope or
side wall. Extending the downrod length will
usually solve this problem.

Suggested Extension Downrod Lengths

Ceiling Height

Downrod Length

9' 0"

standard

9' 6"

standard

10' 0"

12"

10' 6"

12"

11' 0"

18"

12' 0"

24"

13' 0"

36"

14' 0"

48"

15' 0"

60"

7' minimum

Blades must be a

minimum of 7 feet

above the floor

Extension

Downrod

Maximum angle

of Hang-Tru

®

canopy = 32º

This slope is less than 32º.

It is OK to install your fan.

This slope is 32º. This is the

maximum slope that will allow the

fan to hang straight down. It is OK

to install your fan.

This slope is more than 32º. Your

fan will not hang straight down; an

adaptor is necessary. Contact your

local Authorized Casablanca Dealer in

regards to purchasing a Sloped Ceiling

Adapter.