Menu setting table (2/2), 33 printer operation, Mode settings – Citizen Systems CLP-521 User Manual
Page 33
33
Printer Operation
Top Menu
Sub Menu
Default
Menu
Remarks
Function Select
Off
Off
Tear
Peel On
*
Cut On
*
Cutter Action
**
Backfeed
Backfeed
Through
Paper Position
0.00IN
Peel/Cut/Tear Off
0.00mm
0.00 to 2.00 IN
0.0 to 50.8mm
Peel/Cut/Tear On
-1.00 to 1.00 IN
-25.4 to 25.4mm
Mode/Repeat Key
Disabled
LabelSet
LastOne
Disabled
Interfaces
RS-232C Baud
9600
115200
57600
38400
19200
9600
4800
2400
RS-232C Parity
None
None
Odd
Even
RS-232C Length
8 bits
8 bits
7 bits
RS-232C Stop bit
1 bit
1 bit
2 bits
RS-232C X-ON
Yes
Yes
No
IEEE1284
ON
ON
OFF
Selects the type of options installed and
adjusts the "paper stop" position accordingly.
For example, the position where the label stops
in "Tear" mode is different to that in "Peel On"
mode.
Cutter operating method setting
Backfeed: it feeds back after each cutting
operation.
Through: when the number copied = n, the
back end of sheet 1 to n-1 passes through,
and the back end of the final page that is a
single sheet is copied and fed back.
The stop position can be fine tuned using this
menu setting. The general stop position is
selected depending on the "Function" selected
above.
Repeat method selection
LabelSet:
Reissues multiple labels.
LastOne:
Issues only the final page.
In count case, it issues only 1 label while
continuing.
Disabled:
Makes the repeat key invalid.
Sets the baud rate of the serial interface.
• Interface related settings are effective after
the power is turned on again.
Sets the communication parity of the serial
interface.
Sets the character length of the serial interface.
Sets the stop bit of the serial interface.
Selects the X-ON flow control of the serial
interface.
Enable or disables the 'enhanced' features of
the IEEE1284 parallel interface.
Mode Settings
* Effective only when the optional unit is attached.
** Effective only when "Cut On" is selected on the "Menu".
Off ...... Auto configure ineffective.
When a peeler unit or auto-cutter is
installed but has not been started, it
is off and the operation is selected
by “Function select”.