38 chapter4 maintenance mode soft sw setting mode – Citizen Systems CD-S500 Series User Manual

Page 38

background image

38

Chapter4

Maintenance Mode

Soft SW Setting Mode

Buffer Size

4k

40byte

4Kbyte

Init Signal

ENB

ENB

DIS

Buzzer

ON

ON

OFF

Baud Rate

19200

19200

9600
4800
2400
1200

Data Length

8 bit

8 bit

7 bit

Parity Bit

NONE

NONE

EVEN

ODD

Stop Bit

1 bit

1 bit

2 bit

Protocol

DTR

DTR

X-ON-OFF

Paper Width

76.2

76.2

69.5
57.5

Set item

Initial value

Setting value

Remarks

Set item

Initial value

Setting value

Remarks

Set item

Initial value

Setting value

Remarks

The receiving buffer size is selected.

Selects buzzer sound when an abnormality occurs as
enabled (ON)/disabled (OFF).

Sets the baud rate of the serial interface.

Sets the character length of the serial interface.

Sets the communication parity of the serial interface.

Sets the stop bit of the serial interface.

Selects the paper size.

Selects enabled (ENB)/disabled (DIS) of the printer
initialized signal (PRIME) during centro-interface.
Selects enabled (ENB)/disabled (DIS) of the 25pin reset
signal during serial interface.

Mechanical-SW

Interface-SW (Displayed only when the serial board is mounted)

Auto-Cutter

FREE

OFF

FREE
FULL

PAR.

Selects the cutter operation.
When it is OFF, the FULL/PAR. commands do not start
cutting.
In FREE status, cutting is done according to the
FULL/PAR. commands.
In FULL status, full cut is always done by both the
FULL/PAR. commands.
In PAR status, partial cutting is always done by both the
FULL/PAR. commands.