START-UP PROCEDURE

ELECTRICAL CONNECTIONS

To insure proper operation, your new model must be connected to an individual circuit
that can supply the full voltage as stated on the cabinet serial data plate. For correct
voltage, power draw, and wire accommodations, check the data on the serial data
plate located on the inner right wall of your new model. Verify that this information
exactly matches the electrical characteristics at the installation location. An electrical
wiring diagram, located on the upper cabinet end panel next to the electrical console
box, should also be consulted during connection.

Important Note:

The condensing unit supplied with all self-contained models is

designed to operate with a voltage fluctuation of + 10 % of the voltage indicated on
the cabinet serial data plate. Full voltage of the correct service, on an individual line
not affected by the operation of other electrical appliances, must be available to the
condensing unit at all times. Burnout of the compressor due to exceeding the
high or low voltage limits is easily detected and will automatically void the
factory warranty.

115 VOLT, 60 HZ, 1 PHASE CONNECTION

All 115 volt models are provided with a U.L. approved power cord and polarized plug
which is factory installed.

Warning:

Any alterations to this cord and plug could cause an electrical

hazard and will void the factory warranty.
To insure proper operation, this equipment must be plugged into a NEMA 5-15R
compatible, grounded receptacle that can supply the full voltage as stated on the
serial data plate.

208-230 VOLT, 60 HZ, 1 PHASE CONNECTION

All 208-230 volt models are to be permanently connected and are provided with
four (4) field wiring leads which exit the electrical console box located in the
machine compartment behind the front grill. The cabinet circuitry is 115 volts
and the condensing unit is 208-230 volts in which the wiring includes a neutral
and a mechanical ground. This wiring should be connected to the appropriate
power source by a qualified electrician and must conform to all local electrical
codes.

SPECIAL VOLTAGE CONNECTIONS

When models are ordered from the factory with special, optional voltages, connections
should be made as required on the electrical wiring diagram provided on the upper
cabinet end panel next to the electrical console box.