beautypg.com

To operate on fan, You will see, To use the energy save – Sharp AF-S125NX User Manual

Page 13: Timer:timer on/off, You will see how much time is chosen, How to operate

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

HOW TO OPERATE

TO OPERATE ON FAN:

YOU WILL SEE:

LIGHT ON

Note: Use this function only when cooling is not desired, such

as for room air circulation or to exhaust stale air. (Remember

to open the vent during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can choose any

fan speed you prefer.

During this function, the display will show the actual room tem­

perature, not the set temperature as in the cooling mode.

TO USE THE ENERGY
SAVE:

YOU WILL SEE:

6MS>

(SMS’

LIGHT ON

Note: In this mode, the fan will continue to run for 3 minutes

after the compressor shuts off. The fan then cycles on for 2

minutes at 10 minute intervals until the room temperature is

above the set temperature, at which time the compressor turns

back on and cooling starts.

TIMER:TIMER ON/OFF

YOU WILL SEE HOW MUCH TIME IS CHOSEN:

LIGHT ON

Note: For Timer Off, the unit must be in the On position.

Note: For Timer On, the unit must be in the Off position.

To adjust timer setting, tap or hold the UP arrow( A) or the

DOWN arrow(^) to change delay timer at 0.5 hour incre­
ments, up to 10 hours, then at 1 hour increments up to 24
hours. The control will count down the time remaining until

start (8, 7.5, 7, etc.). The Timer On mode automatically
selects cooling with maximum Fan Speed. The temperature

maintained will be the same as previously set. To change the

set temperature, press “MODE” then Up or Down arrows until

the desired temperature is indicated on the display. After 5

seconds, the control will automatically change the display

back to the hours remaining until the unit will start/stop.

Turning the unit “ON” or “OFF” at any time will cancel the Timer

On/Off function.

The Timer On/Off Feature will work until the unit either

starts or stops. Once that happens the above steps have to be

repeated again.

. _

13