Installation instructions, If ac is blocked by storm window, Removing ac from window – Sharp 2020215A0343 User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
INSTALLATION INSTRUCTIONS
3
Keep a firm grip on the air conditioner, carefuliy
place the unit into the window opening so the
bottom of the air conditioner frame is against the
window sill (FIG.6).Carefully close the window behind the
top rail of the unit.
1
To secure lower sash in place, attach right angle
window lock with 3/4'” (
20mm
) screw as shown
(FIG. 11).
FIG. 11
G. 6
Extend the side panels out against the window
frame (FIG.7).
8
Cut foam seal and insert in the space
between the upper and lower sashes
(FIG.12).
5
Place the frame lock between the frame
extensions and the window sill as shown
(FIG.8). Drive 3/4"(
20mm
) locking
screws through the frame lock and into the sill
(FIG.9). NOTE: To prevent window sill from
splitting, drill 1/8" (3 mm) pilot holes before
driving screws.
FIG. 8
If AC is Blocked by Storm Window
Add wood as shown in FIG.13, or remove storm
window before air conditioner is installed.
FIG. 13 n
STORM WINDOW
FRAME
OR OTHER 11/2” MIN
OESTR
l
JCTION pBmml
BOARD
THICKNESS
AS REQUIRED,
-OR PROPER
PRCHTO
REAR. ALONG
ENTIRE SILL.
FASTEN WITH
NAILS OR
SCREWS.
Drive 3/4"(
20mm
) locking screws
through frame holes into window sash
(FIG.10).
R G v I O
If Storm Window Frame must remain, be sure the
drain holes or slots are not caulked or painted shut.
Accumulated Rain Water or Condensation must be
allowed to drain out.
Removing AC From Window
if: Turn AC off, and disconnect power cord.
Remove sash seal from between windows,
and unscrew safety lock.
Remove screws installed through frame and
frame lock.
Close(slide) side panels into frame.
Keeping a firm grip on air conditioner, raise
sash and carefully“rock” air conditioner
backward to drain any condensate water in
base of unit. Be careful not to spill any
remaining waterwhile lifting unit from
window. Store parts WITH air conditioner.