Service Tech Information
The faceplate timer (PWA) computer has a self-diag
nostic function for the electrical system, except for input
power and water meter. The computer monitors elec
tronic components and circuits for correct operation. If a
malfunction occurs, an error code appears in the face
plate display.
The chart below shows the error codes that could
appear, and the possible problems for each code.
Service Required
See Owner’s Manua
Diagnostics
FIG. 62
POSSIBLE PROBLEM
CODE
MOST LIKELY
LESS LIKELY
Erri, ЕггЗ, Err4
wiring harness connections at switch and facepiate not connected / position switch inoperabie / motor inoperabie
Err5
facepiate timer (PWA)
While an error code appears in the display, all faceplate
buttons are inoperable except the SELECT button.
SELECT remains operational so the service person can
make the MANUAL INITIATED ELECTRONIC DIAG
NOSTICS (below) to further isolate the problem, and
check the water meter.
PROCEDURE FOR REMOVING ERROR CODE
FROM FACEPLATE:
1. • Unplug transformer from outlet.
• Plug in transformer.
• Wait for 8 minutes.
2. • Unplug transformer from outlet.
• Correct problem.
• Plug in transformer.
• Wait for 8 minutes.
The error code will return if the problem was not corrected.
MANUAL INITIATED ELECTRONICS DIAGNOSTICS:
1. To enter diagnostics, press the SELECT button once
to go to the Main Menu. Move the black bar to
Service Mode and press Select. Move black bar to
Diagnostics and press Select.
You will see the display, showing valve cycle position,
position switch status (open or closed), and turbine
operation.
TURBINE OPERATION; If no water is flowing through
the softener, the turbine indicator displays 3 zeros.
When water is flowing, a 000 to 140 count repeats for
each gallon of water passing through the turbine. To
check for positive operation of the turbine if zeros are
shown, open a nearby soft water faucet and observe
the turbine count. If you don't get a reading in the dis
play, with faucet open, pull the sensor from the valve
outlet port. Pass a small magnet back and forth in front
of the sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing and
check the turbine for binding.
valve
position
indicator
У
lO : 39 :
lO : 39 : 56 AM
Pos: SERVICE 0 : 00
Pos: SERVICE 0 : 00
Req Pos: SERVICE
Req Pos: SERVICE
Motor: Off —C' D—
Motor: Off —O '0—
Trbn: 0(K) Gafs: 0
Trbn: I26 Gals: 0
Days: I W Rchgs: 0 \
Days: I W Rchgs: 0
East Rch^ 4 'Ч
East Rch‘^4
position
switch
indicator (open)
turbine
count
(no
water flowing)
turbine
count
(water flowing)
FIG. 63
Questions? Call The Kenmore Water Line 1-800-426-9345