Bypass valves, Fig. 59, Model no. 625.384260 - timer code h46 – Kenmore INTELLISOFT 420 SERIES 625.38426 User Manual
Page 36: Il— g —j
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
A
il— g —J
D
C
BYPASS VALVES
Bypass valve(s) should always remain In soft water
service position. Position in “bypass” only if needed for
softener repairs.
SINGLE BYPASS
Inches
cm
A
Salt Tank Height
34
86.4
B
Resin Tank Diameter
(nominal)
10
25.4
C
Resin Tank Height (nominal)
40
101.6
D
Inlet-Outlet Height
41-1/2
105.4
E
Overall Height
48
121.9
Fi
Length
21
53.3
F2
Width
17
43.2
-
Distance between inlet-outlet
centerlines
3-3/4
8.6
Bypass
valve
Inlet
valve
FIG. 59
MODEL NO. 625.384260 - TIMER CODE H46
WATER SUPPOr TO WATER SOFTENER
Minimum water system flow (gpm)
3
Minimum-maximum water pressure (psi)
20 - 125
Minimum-maximum water temperature (°F)
40 - 120
Maximum water hardness (gpg)
160
Maximum “clear water” iron (ppm)*
11
SALT FOR WATER SOFTENER
Type of salt needed
nugget
Alternate type of salt
pure, evaporated, compacted
water softener salt
gpm = gallons per minute gpg = grains per gallon
psi = pounds per square inch ppm = parts per million
' Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires
additional treatment if water supply contains greater than 5 ppm clear water iron.
Questions? Call The Kenmore Water Line 1-800-426-9345