A warning, Awarning, Safety precautions – Kenmore ECONOMIZER 153.332418 User Manual
Page 2: I i i
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Safety Precautions
A WARNING
Improper
installation,
adjustment,
alteration,
service
or
maintenance
can
cause
DEATH,
SERIOUS
BODILY
INjURV, OR PROPERTY DAMAGE. Refer to this manu
al for assistance or consult your local Sears Service
Center for further information.
AWARNING
WATER
HEATERS
EQUIPPED
FOR
ONE
TYPE
GAS
ONLY: This water heater is equipped for one type gas
only. Check the model rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER
HEATER
WITH
ANY
GAS
OTHER
THAN
THE
ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH,
SERIOUS
BODILY
INJURY,
OR
PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.
AWARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ
UIDS
(VAPORS)
ARE
LIKELY
TO
BE
PRESENT
OR
STORED
(GARAGES,
STORAGE,
AND
UTILITY
AREAS,
ETC);
Flammable
liquids
(such
as
gasoline,
solvents,
propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as
property damage.
If installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline
and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
AWARNING
If this water heater will be used in beauty shops, barber
shops, cleaning establishments, or self-service laundries
with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com
bustion and ventilation air be taken from outside these
areas.
Refer
to
the
"Facts
to
Consider
About
the
Location” section of this manual and also the latest edi
tion of the National Fuel Gas Code, ANSI Z223.I, also
referred to as NFPA 54 for specifics prcwided concerning
air required.
AWARNING
A fire can start if combustible materials such as clothing,
cleaning materials, or flammable liquids are placed against
or next to the water heater.
AWARNING
At the time of manufacture this water heater was provid
ed with a combination temperature-pressures relief valve
certified
by
a
nationally
recognized
testing
laboratory
that maintains periodic inspection of production of listed
equipment
or
materials,
as
meeting
the
requirements
for Relief Valves and Automatic Gas Shutoff Devices for
Hot Water Supply Systems, and the latest edition of
ANSI Z2I.22 and the code requirements of ASME. If
replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as meeting the require
ments
for
Relief
Valves
and
Automatic
Gas
Shutoff
Devices for Hot Water Supply Systems, ANSI Z2I.22 by
a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or
materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure
of the water heater (ISO Ibs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters •
watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the
use
of
a
temperature-pressure
reliqf
vidve
{complying
with ANSI Z2I.22 anc( ASnE,imay requir^ a^ '
'
different from the onelfurnished with фе wat
Compliance with sucH 1оф1 requirements! m
fied by the installer oijend иЦг of thd water
a locally prescribed temberdture-prbssure
: in
Ive model
heater,
be satis-
leater with
jelief valve
the watdr heater in
peatjer,
lesionali
’e ms
lief valve
pening or
installed
installed in the designatecqopmin^
place of the factory futnisfled yalw
For safe operation on the water
must not be removed fr^m ft's
plugged.
I i I
The temperature-pressurt refeef ^
,
directly
into
the
fitting
of
thf
waiter:beAeridesignated
for the relief valve. PopiticAi the valyp d
and pro
vide tubing so that ally décharge iMlf ex^ oRly within 6
inches above, or at any distance below the structural
floor. Be certain that
tio
contact'is nVSde.;with any live
electrical
part.
The
discharge
opening
must
not
be
blocked or reduced in size under any circumstances.
Excessive length, over 30 feet, or use of more than four
elbows cam cause restriction and reduce the discharge
capacity of the valve.
No valve or other obstruction is to be placed between
the relief valve and the tank. Do not connect tubing
directly to discharge drain unless a 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam
age, the relief valve must be allowed to discharge water
in quantities should circumstances demand. If the dis
charge pipe is not connected to a drain or other suitable
means, die water flow may cause property damage.
The Discharge Pipe:
* Must not be smaller in size than the outlet pipe size of
the valve, or have any reducing couplings or other
restrictions.
* Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
•
Must be installed so as to allow complete drainage of
both
the
temperature-pressure
relief
valve,
and
the
discharge pipe.
• Must terTnjnate at an adequate drain.
* Must not have any valve between the relief valve and
tank.