PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Tested and certified by NSF Internationai against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average % NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.04 mg/L
N/A
97.9%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99.97%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average % NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction Number
Cyst
99.95%**
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.1 NTU
0.09 NTU
99.5%
99.69%
994710
Lead: @
pH 6.5
0.015 mg/L
0.16 mg/L***
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead: @
pH 8.5
0.015 mg/L
0.16 mg/L***
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
Base Grille Water Filtration System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average % NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction Number
Chlorine Taste/Odor
N/A
2.0 mg/L
N/A
0.04 mg/L
N/A
98%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average % NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction Number
Cyst
99.95%**
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.12 NTU
0.09 NTU
99.59%
99.69%
994710
Lead: @
pH 6.5
0.015 mg/L
0.16 mg/L***
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead: @
pH 8.5
0.015 mg/L
0.16 mg/L***
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
Refer to the front cover or “Assistance or Service” section for
the Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30- 120 psi (207 - 827 kPa)
Water Temperature
33°-100°F(0.6°-37.8° C)
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NLC250
Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2002 suggested retail price of $39.95 U.S.A./$49.95 Canada.
Prices are subject to change without notice.
Model WF-LC400
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 9902. 2002 suggested retail price of $39.95 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
* Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.
** Cyst performance is % reduction based on NSF Standard 53.
** Test requirement is 0.15 mg/L ±10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water
conditions.
I NSF is a registered trademark of NSF International.