Thank

You for purchasing a Sears water heater. Properly

installed and maintained, it should give you years of trouble

free service. It is strongly suggested that this new water heater
be professionally installed, contact the local Sears Service
Center or any Sears store. They will arrange for prompt, quality

installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

UL - Underwriters Laboratories Inc.

NEC - National Electrical Code

ANSI - American National Standards Institute

Read the “General Safety” section, page 3 of this manual

first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could

cause

DEATH,

SERIOUS

BODILY

INJURY

AND/OR

PROPERTY DAMAGE.

This

manual

contains

instructions

for

the

installation,

operation, and maintenance of this electric water heater. It
also contains warnings throughout the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER,

The installation must conform with the instructions in this

manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the

NEC - National Electrical Code, NFPA 70. This publication
is available from your local government or public library or

electric company or by writing Underwriters Laboratories

Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call Sears
Service Center.

• Carefully plan the place where you are going to put the water

heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock

and fires.

Examine the location to ensure the water heater complies with

the

“Facts to Consider About the Location"

section.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Cffice of the
State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed
in

accordance

with

Massachusetts

248-CMR

2.00;

State

Plumbing Code and 248-CMR 5.00. In the Commonwealth of
Massachusetts, this product must be installed by a licensed
plumber or gasfitter.

MODEL

NUMBER

TANK

CAPACITY

IN GALLONS

DIME

IN INCf

NSIONS
IES (mm)

RECOVERYRATE

GALS.PERHOUR

(®,90»F Rise

ELEMENT

WATTAGE

@ 240 VOLTS

MINIMUM

WIRE SIZE*

(GAUGE)

MAXIMUM FUSE

OR CIRCUIT

BREAKER

SIZE (AMPS)

DIA.

HEIGHT

UPPER

LOWER

153.326362
153.326363

30

18.0 (457)

46.5 (1181)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326462
153.326463

40

18.0 (457)

59.5 (1511)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326562
153.326563

55

20.5 (521)

60.25 (1530)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326662
153.326663

50

23.0 (584)

49.0 (1245)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326762
153.326763

40

20.5 (521)

44.0 (1118)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326862
153.326863

50

26.5 (673)

34.0 (864)

17.3

3800

3800

12

20

25.0

3800

5500

10

30

"Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local
electrical code.