beautypg.com

A warning, Converting, Fire hazard / electric shock hazard – Kenmore 153 User Manual

Page 12: The lower element

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Converting

the Lower Element

These instructions only cover the conversion of the convertible
element, read this entire manual before attempting to install or
operate the water heater. The water heater is factory set to
operate at 3800 watts. The lower element can be converted to
operate at 5500 watts. Refer to

Tacts to Consider About the

Convertible Lower Element”

section.

The

Upper

Element,

(if

double

element

model)

is

a

conventional 3800 watt element which only operates at its rated
wattage on 240 volts. (See rating plate on the water heater.

The lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.

Necessary element conversion parts are located in a small
bag contained within the electrical junction box on top of the

water heater.

CONVERSION PARTS

BUSS BAR

SCREW

FIGURE 12.

If after reading these instructions and this manual, if you do not

understand any portion call Sears Service Center.

..A WARNING

Fire Hazard / Electric Shock Hazard

é

• Do not use this water heater with

any voltage otherthan shown on the
model rating plate.

'>é

V

• Failure to use the correct voltage

shown on the model rating plate
could result in death, serious bodily
injury, or property damage.

Before making the conversion to 5500 watts, check the (1)
power supply . . . must be 240 volts, (2) wiring . . . 10 gauge

AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers
or fusing . . .capable of 30 amp loading. Also, the installation

must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY

INJURY, OR PROPERTY DAMAGE,

NOTE:

Whether or not the element conversion is made the

model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating plate,

which is located adjacent to the lower access panel.

1.

Before beginning the conversion turn “OFF” electric power
supply to the water heater.

2

.

The convertible element is located behind the lower
access panel of the water heater. Remove the two screws
securing the access panel, and remove panel.

3.

Remove the insulation cap with handle to expose the

terminal cover.

ELECTRIC

WATER HEATER

MODEL NUMBER

CAPACITY

U.S. GAL.

LISTED

932N

SERIAL NUMBER

FACTORY EQUIPPED WITH

MAXIMUM

UPPER LOWER

CHECK HERE WORKING

ELEMENT ELEMENT MAXIMUM VOLTS IF INSTALLED AS PRESSURE

WATTS WATTS WATTS A.C.ONLY FACTORY EQUIPPED P.S-I,

OPTIONAL WATTAGE

UPPER LOWER

ELEMENT ELEMENT MAXIMUM

WATTS WATTS WATTS

CHECK HERE

IF CONVERTED

WARNING

SEE CONVERSION

INSTRUCTION

FIGURE 11.

FIGURE 1S.

4.

Lower Element: Lift out the tab as shown to unclip the

terminal cover from the thermostat. The terminal cover can
now be removed from the thermostat.

12