Awarning, Installation instructions (cont’d) – Kenmore POWER MISER 153.32154 User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installation Instructions (cont’d)
The convertible element is located, behind, the lower access
panel of the wmer hcatcj', 'Remove the two screws securing
the access panel, and remove panel.
3. Remove the insulation block and pad.
4. Lower Elemeut: Lift out the tab as shown to unclip the ter
minal cover from the thermostat. The terminal cover can be
removed from the thermostat.
,5. Remove the screws from terminal 2 of the element, and. move
the looped end, of the wire asid e.
6. The buss bar is labeled 5.500 W. Place the buss bar over
terminals 2 and 3 with the 5.500 W visible. Install the extra
screw provided, into terminal 3.
The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
8. Tighten terminals 2 and 3 to ensure proper electrical
connection.
AWARNING
Failure to tighten terminal screws can cause a Pre which
can result In DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.