Figure 7: Optional Piping for Circulation Systems
NOTE:
Applications, using this piping 
arrangement reduces the 
warranty to the following:
3 years on heat exchanger
3 year on parts
Full warranty will be maintained if an 
on-demand recirculation system in 
incorporated. Refer to the Limited 
Warranty.
For this application:
Pump should be controlled by an Aquastat,
Timer or Combination Aquastat and Timer.
Pump to be sized to maintain circulation 
loop temperature.
A minimum of 3 GPM flow is recommended 
for the circulation system.
The pump should be sized to overcome the
pressure loss through the water heater,
supply and return plumbing.
Pump to be of bronze or stainless construe
tion.
Note:
I °o n o° I
o
o
N
r
s
Water Heater
-
\
o
o
/
Equipment List
QTY
Water Heaters
1
Plumbing Installation 1 
Kit (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain Valves and 
1 Pressure Relief Valve.)
3/4" Gas Connection
Water heater outlet temperature
cannot be adjusted when 
circulation pump is running.
Minimum 3/4" Hot Water
Supply Line
Minimum 3/4“ Cold Wbter Supply Une
(Optional)
2-6 Gallon 
Storage Tank
(To eliminate cold water 
sandwich effect caused by 
frequent On/Off operation)
Building Fixture Outlets
rm
Expansion Tank
KEY
3/4" Ball Valve
s
Pressure Regulator
3/4" Union
m
Circulating Pump
Check Valve
fgj
Boiler Drain Valve
Pressure Relief Valve
[ft
Solenoid Valve
This is not an engineered drawing. It is intended only as a guide and not 
as a replacement for professionally engineered project drawings. This 
drawing is not intended to describe a complete system. It is up to the 
contractor/engineer to determine the necessary components and 
configuration of the particular system being installed. This drawing does 
not imply compliance with local building code requirements. It is the 
responsibility of the contractor/engineer to ensure installation is in 
accordance with all local building codes. Confer with local building 
officials before installation.
305 & 505 Outdoor Manual