CAUTION

Mineral Buildup or Sediment May Accumulate

This causes the water heater to become

much heavierthan normal.
If spilled, could cause staining.

Mineral buildup or sediment may have accumulated in the

old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could cause
staining.

Facts to Consider About the Location________

You should carefully choose an indoor location for the new water
heater, because the placement is a very important consideration
for the safety of the occupants in the building and for the most
economical use of the appliance. This water heater is not

intended for outdoor installation.

Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed.

• The location selected should be indoors as close to and as

centralized with the water piping system as possible. This

water heater, as well as all water heaters, will eventually leak.

Do not install without adequate drainage provisions so water

flow will not cause damage.

CAUTION

Property Damage Hazard

All water heaters eventually leak

Do not install without adequate drainage.

WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not cause
damage to the structure. When such locations cannot be avoided,
a suitable metal drain pan should be installed under the water
heater. Drain pans are available at your local Sears stores. Such
drain pans must be piped to an adequate drain.

Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a metal drain pan
piped to a drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used

in conjunction with a piped metal drain pan. These devices are
available from some plumbing supply wholesalers and retailers,
and detect and react to leakage in various ways:

• Sensors mounted in the metal drain pan thattriggeran alarm orturn

offthe incoming waterto the waterheaterwhen leakage is detected.

Sensors mounted in the metal drain pan that turn off the

water supply to the entire home when water is detected in the
drain pan.

Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water pipes
connected to the water heater.

CAUTION

Installations in Residential Garages

• Water heater must be located in a

protective area.

INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical

damage by a moving vehicle.

• The location selection must provide adequate clearances for

servicing and proper operation of the water heater.

Insulation Blankets_______________________

Insulation blankets are available to the general public for external

use on electric water heaters but are not necessary with this
product. The purpose of an insulation blanket is to reduce
the standby heat loss encountered with storage tank heaters.
Your water heater meets or exceeds the National Appliance
Energy Conversation Act standards with respect to insulation
and standby loss requirements, making an insulation blanket
unnecessary.

Should you choose to apply an insulation blanket to this heater,
you should follow these instructions below. Failure to follow these
instructions can result in fire, serious personal injury, or death.

• Do not cover the temperature and pressure relief (T & P) valve

with an insulation blanket.

• Do not cover the instruction manual. Keep it on the side of

the water heater or nearby for future reference.

• Do obtain new warning and instruction labels for placement

on the blanket directly over the existing labels.

Water Piping

ADANGER

Water temperature over 125°F

(52°C) can cause severe burns
instantly resulting in severe injury
or death.

Children, the elderly, and the
physically or mentally disabled
are at highest riskfor scald injury.

Feel water before bathing or

showering.

Temperature limiting valves are

available.

Read instruction manual for safe