These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME {1-800-469-4663)
for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.
improperly sealed, hot or cold supply connection,
Tighten threaded connections.
WATER LEAKS
relief valve, drain valve, or thermostat threads.
Leakage from other appliances or water lines.
Inspect other appliances near water heater.
Condensation of flue products.
Refer to CONDENSATION.
Thermal expansion in closed water system.
Install thermal expansion tank (DO NOT plug T&P valve).
LEAKING T&P VALVE
Improperly seated valve.
Check relief valve for proper operation
(DO NOT plug T&P valve).
SMELLY ODORS
High sulfate or mineral content in water supply. Drain and flush heater thoroughly, then refill.
Bacteria in water supply.
Chlorinate or aerate water supply.
Gas control knob not positioned correctly.
Refer to LIGHTING INSTRUCTIONS.
Main gas supply off.
Turn on main gas Shut-off valve.
igniter tip more than 1/8" from pilot hood.
Adjust ignitor tip.
Thermocouple malfunction.
Replace pitot assembly.
Thermocouple TCO malfunction.
Replace pitot assembly.
Melted insulation on ignitor wire or shorting
Contact Sears Service to determine cause.
PILOT WILL NOT LIGHT
of ignitor wire.
High ambient room temperature.
Contact Sears Service to determine cause.
Wire disconnected from spark ignitor.
Reconnect wire connector to spark ignitor.
Broken electrode or electrical wire.
Replace pitot assembly.
Piezo Ignitor generator fails to operate or
malfunctions.
Replace Piezo Ignitor generator.
Thermocouple TCO malfunction.
Replace pitot assembly.
High ambient room temperature.
Contact Sears Service to
determine cause.
BURNER WILL NOT
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
STAY LIT
Flame arrestor openings blocked.
Contact Sears Service to
determine cause.
Defective Gas Control.
Replace Gas Control.
Dirty pilot burner.
Clean pitot assembly.
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
PILOT OUTAGE
Thermocouple tip is not in contact with pilot flame.
insert thermocouple correctly.
Thermocouple malfunction.
Replace pitot assembly.
Thermocouple TCO malfunction.
Replace pitot assembly.
Defective Gas Control.
Replace Gas Control.
Heater not lit or thermostat not on.
Refer to LIGHTING INSTRUCTIONS.
Thermostat set too low.
Refer to TEMPERATURE REGULATION.
Heater undersized.
Reduce hot water use.
NOTENOUGH
Low gas pressure.
Contact your gas supplier.
HOT WATER
Incoming water is unusually cold.
Allow more time for heater to re-heat.
Leaking hot water pipes or fixtures.
Have plumber check and repair leaks.
High temperature limit switch activated.
Contact Sears Service to
determine cause.
WATER TOO HOT
Thermostat set too high.
Refer to TEMPERATURE REGULATION.
WATER HEATER SOUNDS
Condensation dripping on burner.
Refer to CONDENSATION.
SIZZLING - RUMBLING
Sediment or calcium in bottom of heater tank.
Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual.
SOOTING
improper combustion.
No adjustment available. Contact Sears Service
to determine cause.
Lack of supply air.
VENT GAS ODORS
improperly installed vent piping.
Contact Sears Service to determine cause.
Downdraft.
Poor combustion.
26