beautypg.com

High temperature shut off system, Awarning, Not enough or no hot water – Kenmore 153.33439 User Manual

Page 24: Water is too hot, Troubleshooting guide (cont’d), Operational conditions (cont’d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Operational Conditions
(cont’d)

HIGH TEMPERATURE SHUT OFF SYSTEM

Troubleshooting Guide (cont’d)

This water heater is equipped with an automatic gas shut off sys'
tern. The high temperature shut off is built into the gas control
valve. This system shuts off the gas supply to the water heater
burners when high water temperatures are present. !t is non­

resettable. If the high temperature shut off activates, the gas con­
trol valve must be replaced. If this were to occur, turn “OFF” the

entire gas supply to the water heater. Contact the Sears Service
Center.

AWARNING

Should overheating occur or the gas supply fail to shut off,

turn “OFF” the manual gas control valve to the appliance.

NOT ENOUGH OR NO HOT WATER

• Check the manual gas shut off valve to be sure it is open.
• Check the pilot flame. It may have gone out. All models have

an opening behind the outer door for viewing the pilot.

• If the pilot is not lit, follow the “Lighting” instructions in this

manual or located above the gas control valve on the water

heater to relight the pilot. If the water was extremely hot and is

now cold, the high limit safety temperature shut off may have

put out the burner and pilot. If the high temperature shut off

activates, the gas control valve must be replaced. Contact the
Sears Service Center.

• Tlie gas control knob must be turned to the “ON” position.
• The temperature adjustment dial may be set too low. See the

“Temperature Regulation” section.

• The gas company can check the gas input to see if it is correct.

An underfired water heater will not heat water as quickly.

• Look for leaking or open hot wrater &ucecs. Make sure all are

closed.

• The cold water inlet temperature may be colder during the winter

months. It will take longer to heat the wrater and seem like
less hot water.

• If you cannot find what is wrong, call the Sears Service Center.

WATER IS TOO HOT

• The temperature adjustment dial may be set too high. See the

“Temperature Adjustment” section.
NOTE: A period of time is necessary after an adjustment
has been made ftir the water temperature to teach the new
temperature setting.

• If lower temperature settin« will not lower the water tempera­

ture, call the Sears Service Center.

AWARNING

HOTTER WATER CAN SCALD: Witer heaters are intended to
pn^uce hot wrater. Water heated to a temperature which will
satisfy dathes washing, dish washing, and otiier sanitizing ne^s
can scald and permanently injure you upon contact Some peo­
ple are more likely to be permanently injured by hot water tfon

others. These include the elderly, diildren, the Infimi, or physical-
ly/mentally handicapped. If anyone using hot water in your home
fits into one of these groups or № there is a local code or state law
requiring a certain temperature water at the hot water tap, then
you must take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water needs,
a means such as a mixing valve, should be used at the hot water
taps used by these people or at the water heater. Mixing valves
are available at plumbing supply or hardware stores. Follow man­

ufacturers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the

'Temperature Regulation” section in this manual.

AWARNING

Due to the nature of the typical gas water heater, the

water temperature in certain situations may be hotter
than the thermostat setting.

Short, frequent draws of hot water - especially with very

cold incoming water • can shock the thermostat into brief
operation resulting in hotter and hotter layers of water

closer to the top of the tank.
Changes in hot water usage patterns or raising the tem­
perature differential between the cut-on of the thermo­
stat and the cold water temperature will usually eliminate

the problem.

24