During this time the room
humidity levei wiii continue to be
monitored and the humidifier will cycie
the fan on and off untii the fiiter is
compietely dry. The fan will shut off
leaving you with a dry humidifier that is
less prone to mold and mildew growth.
If
DRY OUT MODE
Is not desired, refill
the humidifier with water and the fan will
return to the set speed.
NOTE:
Fan automatically switches to
lowest speed during
DRY OUT MODE.
Check
Filter Indicator
The ability of any humidifier to efficiently
supply humidity output relies heavily on the
condition of the filter. As the filter loads with
impurities it gradually loses its wicking
capability. When this happens, moisture
output is reduced and the humidifier has to
work longer to satisfy the selected setting.
This humidifier has a check filter reminder
timed to appear after 720 hours of
operation. When the display shows an
alternating “CF” and “room humidity”
setting at 5 second intervals it is a
reminder to check the filter condition.
NOTE:
Some areas have high water
mineral content causing the need for more
frequent filter changes.
Refer to “Replacement and Care of Filter”
on page 10. if a build-up of deposits or
severe discoloration is evident replace the
filter to restore maximum efficiency.
Quiet Comfort
r c
u r
___
Check Filter^
Display
Humidistat
The humidistat located on the power cord
senses the percentage of humidity in the
air. It causes the humidifier to cycie on
and off to maintain the selected humidity
SET
point. The fan will turn on if the
“ROOM”
reading falls 3% below the
SET
point and will continue to run the
humidifier until a reading of 1% above the
SET
point is achieved. The fan will turn
off until the
ROOM
reading falls 3%
below the
SET
point again.
Control Lock Out
To avoid unwanted tampering with the
humidifier settings the controls can be
locked.
Activation Procedure
After the humidifier functions have been
set up, hold the power button down for 5
seconds. The display will show
“CL”
for
2 seconds; release the power button and
the control will resume the display of the
room humidity. The room humidifier will
continue to function with the locked in
settings. If buttons are operated whiie
“CL”
is active, the
“CL”
is displayed and
settings are unaffected.
Deactivation Procedure
To deactivate the
“CL”
function simply
press and hold the power button for 5
seconds.
“CL”
will flash at the rate of
1 second on and 1 second off for a
period of 2 seconds and then resume the
display of room humidity.
NOTE:
Be sure humidistat located
approximately 4 inches outside humidifier
body on power cord is free from
obstruction and away from any hot air
register.