Troubleshooting Guide

Start Up Conditions

CONDENSATION

Whenever the water heater is filled with cold water, a certain

amount of condensation will form while the burner is on. A

water heater may appear to be leaking when in fact the water is

condensation. This usually happens when:

• When a new water heater is filled with cold water for the

first time.

• When gas burns and water vapor is produced in water

heaters, particularly high efficiency models where flue tem­

peratures are lower.

• When you use large amounts of hot water in a short time

and the refill water is very cold.

Moisture from the products of combustion condense on the

cooler tank surfaces and form drops of water which may fall

onto the burner or other hot surfaces to produce a “sizzling" or

“flying” noise.

Excessive condensation can cause pilot outage due to water run­

ning down the flue tube onto the main burner and putting out

the pilot.
Because of the suddenness and amount of water, condensation

water may be diagnosed as a “tank leak". After the water in the

tank warms up (about 1-2 hours), the condition should

disappear.
Do not assume the water heater is leaking until there has been

enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation. The

water heater must be sized properly to meet the family’s

demands for hot water including dishwashers, washing machines

and shower heads.

Excessive condensation may be noticed during the winter and

early spring months when incoming water temperatures are at

their lowest.
Good venting is essential for a gas fired water heater to operate

properly as well as to carry away products of combustion and

water vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and

odor during the initial start-up. This is due to burning off of oil

from metal parts, and will disappear in a short while.

THERMAL EXPANSION

Water supply systems may, because of high line pressure, fre­

quent cut-offs, the effects of water hammer and others, have

installed devices such as pressure reducing valves, check valves,

back flow preventers, etc. to control these types of problems.

When these devices are not equipped with an internal by-pass,

and no other measures are taken, the devices cause the water sys­

tem to be closed. As water is heated, it expands (thermal expan­

sion) and closed systems do not allow for the expansion of heat­

ed water.
The water within the water heater tank expands as it is heated

and increases the pressure of the water system. If the relieving

point of the water heater’s temperature-pressure relief valve is

reached, the valve will relieve the excess pressure. The tempera­

ture-pressure relief valve is not intended for the constant

relief of thermal expansion. This is an unacceptable condition

and must be corrected.
It is recommended that any devices installed which could create

a closed system have a by-pass and/or the system have an expan­

sion tank to relieve the pressure built by thermal expansion in

the water system. Expansion tanks are available for ordering

through the Sears Service Center, Contact the local plumbing

inspector, water supplier, and/or the Sears Service Center for

assistance in controlling these situations.

Thermal Expansion Tank Specifications

Model

Number

Tank Capacity

In Gallons

Dimensions in Inches Pipe Fitting

On Tank

Diameter Length

153.331020

2

8

inches

12%

inches y;' Male

153.331050

5

11

inches

14%

inches y" Male

AWARNING

HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. VWter heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing needs

can scald and permanently injure you upon contact Some peo­
ple are more likely to be permanently injured by hot water than

others. These include the elderly, children, the infirm, or physical-
ly/mentally handicapped. If anyone using hot water in your home
to into one of these groups or if th»e is a local code or state law

requiring a certain temperature water at the hot water tap, then

you must take special precautions. In addition to using the lowest

possible temperature setting that satisfies your hot water needs,
a means such as a mixing valve, should be used at the hot water
taps used by these people or at the water heater. Mbdng valves
are available at plumbing supply or hardware stores. Follow man­
ufacturers instructions for instidlation of the valves. Before

changing the factory setting on the thermostat, read the

‘Temperature Regulation'* section in this manual.

Expansion Tank Sizing Chart

Inlet*

Water Heater Capacity (Gallons)

1 Water

Pressure

30

40

50

66

82

Tank

40psi

2

2

2

i 5

5

Capacity 50psi

2

1

2

2

I

5

5

Needed 60psi

2

j 2

5 ■ 5

5

70 psi

2

1

2

5

5

5

80psi

2

5

5

5

5

"Highest recorded inlet water pressure in a 24 hour period or

regulated water pressure.

NOTE: Expansion tanks are pre-charged with a 40 psl air

charge. If the inlet water pressure is higher than 40 psi, the

expansion tank’s air pressure must be adjusted to match that

pressure, but must not be higher than 80 psi.

22