beautypg.com

Temperature-pressure relief valve operation, Fire and explosion hazard, Anode rod inspection – Kenmore 153.331492 User Manual

Page 26: Draining and flushing, Burner inspection, Draining and flushing -27, Caution, Adanger

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Housekeeping

Temperature-Pressure Relief Valve Operation

Vacuum around base of water heater for dust, dirt, and lint on

a regular basis.

The temperature-pressure relief valve must be manually
operated at least once a year.

ADANGER

Fire and Explosion Hazard

Do not obstruct combustion air

openings at the bottom of the

water heater.

Do not use or store flammable

vapor products such as gasoline,

solvents or adhesives in the

same room or area near water

heater or other appliance.

At least annually, check the

base-ring filter and flame arrestor

for any dust, lint, or debris that

may have accumulated. Clean

as necessary.

Can cause serious injury or death.

AT LEAST ANNUALLY, A VISUAL INSPECTION SHOULD BE
MADE OF THE BASE-RING FILTER AND FLAME ARRESTOR.
CLEAN IF LINT ACCUMULATIONS ARE NOTICED.

INSTALLED IN SUITABLE AREA: To ensure sufficient ventilation

and combustion air supply, proper clearances from the water
heater must be maintained. See “Installation Instructions.”
Combustible materials such as clothing, cleaning materials, or

flammable liquids, etc. must not be placed against or adjacent
to the water heater because they could catch on fire.

Anode Rod Inspection

CAUTION

Property Damage Hazard

■ Avoid water heater damage.

' Inspection and replacement of anode rod required.

The anode rod is used to protect the tank from corrosion.

Most hot water tanks are equipped with an anode rod. The

submerged rod deteriorates to protect the tank. Instead of
corroding the tank, water ions attack and eat away the anode
rod. This does not affect the water’s taste or color. The rod

must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not

necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/
or replaced more often than an anode rod that appears to be
intact. Replacement of a depleted anode rod can extend the
life of your water heater. Inspection should be conducted by
calling the Sears Service Center for an authorized contractor.

At a minimum, the anode(s) should be checked annually after
the warranty period.

When checking the temperature-pressure relief valve operation,

make sure that (1 ) no one is in front of or around the outlet of

the temperature-pressure relief valve discharge line, and (2)
that the water discharge will not cause any property damage, as
the water may be extremely hot. See Figure 30.

TEMPERATURE-PRESSURE

FIGURE 30.

If after manually operating the valve, it fails to completely reset

and continues to release water, immediately close the cold

water inlet to the water heater, follow the draining instructions,

and replace the temperature-pressure relief valve with a new
one.

If the temperature-pressure relief valve on the appliance

weeps or discharges periodically, this may be due to thermal
expansion. You may have a check valve installed in the
water line or a water meter with a check valve. Consult the

Sears Service Center for further information. Do not plug the
temperature-pressure relief valve.

Draining and Flushing

ADANGER

• Hotwaterdischarge burn hazard.

• Keep clear of relief valve discharge

unit.

• Temperature limiting valves are

available.

• Read instruction manual for safe

temperature setting.

It is recommended that the tank be drained and flushed

every 6 months to remove sediment which may build up during
operation. The water heater should be drained if being shut

26