Dimensions and specifications – Kenmore 625.385700 User Manual
Page 18
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
- DIMENSIONS and SPECIFICATIONS -
15”
STORAGE
TANK
9” dia.
11
”
13”
Supply water pressure limits................................................. 40 -- 100 psi
Supply water temperature limits............................................ 40 - 100 °F
Maximum total dissolved solids (TDS) ................................. 2000 ppm
Maximum water hardness @ 6.9 pH..................................... 10 gpg
Maximum iron, manganese, hydrogen sulfide...................... 0
Chlorine in water supply (max. ppm) ................................... 2.0
Supply water pH limits (pH) .................................................. 4 - 1 0
Product (quality) water, 24 hours
CD
...................................... 14 gal.
Waste water per gallon of product water
CD
.......................... 5 gal.
Percent rejection of TDS, minimum (new membrane)
CD
90 - 95
Storage tank capacity (max.) ............................................... 2.3 gal.
Automatic shutoff control....................................................... yes
Efficiency (2) ......................................................................... 8%
Recovery cs).......................................................................... 16 %
Metric
280 - 690 kPa
5 - 40°C
53 liters
18.9 liters
8.7 liters
This system conforms to NSF/ANSI 58 for the specific performance claims as verified and sub
stantiated by test data.
(D
Feed water supply at 50 psi, 77°^ and 750 TDS - Quality water production, amount of waste
water and percent rejection all vary with changes in pressure, temperature and total dissolved
solids.
(2)
Efficiency rating means the percentage of the influent water to the system that is available to
the user as reverse osmosis treated water under operating conditions that approximate typical
daily usage.
(3) Recovery rating means the percentage of the influent water to the membrane portion of the
system that is available to the user as reverse osmosis treated water when the system is operated
without a storage tank or when the storage tank is bypassed.
Problems, Questions? Call 1
18