- CARE OF YOUR REVERSE OSMOSIS SYSTEM
TUBING CONNECTION
(all push- in fitting locations)
This RO system includes push- in fittings for quick
tubing connection at most locations. If working with
the fittings, do the following.
Connection (Figure 14):
1. Use a sharp cutter or knife to cut the end of tubing
square.
2. Inspect the end (about 1") of the tubing to be sure
there are no nicks, scratches or other rough spots. If
needed, cut the tubing again.
3. Push tubing through the collet and all the way into
fitting. Full engagement is 11/16" for 1/4" tubing,
and 3 / 4" for 3 / 8" tubing.
If using tubing other than tubing supplied with the
system, be sure it is of high quality, exact size and
roundness with a smooth surface.
Tubing correctiy cut and connected
collet.
cut tubing square
end of tubing round and
smooth, with no cuts,
nicks or flat spots
11/16" (1/4" tubing)
engagement
3/4^' (3/8" tubing)
Figure 14
To Disconnect Tubing (Figure 15): Push the collet in
ward and hold with a finger while pulling the tubing
out.
Changing Collet and O-ring (Figure 15):
1. With a small screwdriver remove the collet and o
ring from the fitting. Be careful not to scratch the in
ternal walls of the collet port.
2. Be sure the port is clean, then lubricate and insert
the o-ring seal to the bottom of the port.
3. Push the collet inward until it locks in place.
CAUTION
DO NOT USE VINEGAR OR OTHER ACID BASED
CLEANERS ON THIS RO SYSTEM. THEY WILL
DEGRADE SOME RO SYSTEM PARTS. ALWAYS
USE SOAP AND WATER.
I-.
r'
. J
■n
This reverse osmosis system contains a replaceable
treatment component critical to the efficiency of the
system. Replacement of the reverse osmosis compo
nent should be with one of identical specifications,
as defined by the manufacturer; to assure the same
efficiency and contaminant reduction performance.
AUTOMATIC SHUTOFF SERVICE
If the shutoff assembly requires service, be sure to
reassemble parts exactly as shown in Figure 16.
Figure 16
16