Installing option-for ge monogram, Installation instructions – GE PHP900SMSS User Manual
Page 5
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Installation Instructions
INSTALLING OPTION-FOR GE MONOGRAM
MONOGRAM INDUCTION COOKTOP
AND MONOGRAM DOWNDRAFT VENT
COMBINATION INSTALLATION ONLY.
The installation of the downdraft vent with this
cooktop requires careful consideration. Both the
cooktop and the vent must be installed according
to each specific installation instruction.
COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to
accommodate the cooktop and vent. Countertops
with a rolled front edge and backsplash will not
provide the flat surface area required.
• Review the illustration to determine the countertop
surface requirements.
- All cutout clearances for this installation must be
observed.
29-7/8" SS -
29-3/4" Block
2-3/4"
22-3/8"
cutout
depth
19-5/8"
cooktop
cutout
depth
28-1/2" cooktop and vent
---- area cutout---------
1-1/32" cooktop overlap at center
--------------------*------T-----------
Front edge of countertop
1
/
8
"
gap
1-3/4" min. cooktop
cutout to rear vertical
combustible surface
23-1/2" SS
23-3/8" Block
total flat surface
required
at center
-1/2" min. clearance
to cutout
2-1/2"to
Cutout
-3/4" min. cutout to
wall, both sides
1-7/8"
BASE CABINET R EQUIREMENTS
The combined installation will fit in a standard 24"
deep base cabinet. Use a 30" or wider base cabinet.
- The vent housing, blower and ductwork will
occupy the base cabinet.
3/4"
20-3/8"
Vent
22-3/4" Inside
22" to Support Rail
T
3/4"
Thick
Support
Rail