beautypg.com

Device setup troubleshooting, Table 4-6 – Cabletron Systems 6H258-17 User Manual

Page 45

background image

Troubleshooting Checklist

Troubleshooting

4-9

Table 4-6

Device Setup Troubleshooting

Possible Causes

Instruction

The SmartSwitch detect a
looped condition.

1. Verify that Spanning Tree is enabled. Refer to the Local

Management User’s Guide for instructions on setting the
type of STA.

2. Review network design and delete unnecessary loops.

Mode switch (7),
NVRAM Reset, was
changed sometime before
either cycling power or
pressing the RESET
button, causing the
user-entered parameters to
reset to factory default
settings.

1. Reenter the lost parameters as necessary. Refer to the Local

Management User’s Guide for instructions on configuring
the device through Local Management.

2. Call Cabletron Systems if the problem continues.

Clear NVRAM was set
through Local
Management.

1. Reenter the lost parameters as necessary. Refer to the Local

Management User’s Guide for instructions on configuring
the device through Local Management.

2. Call Cabletron Systems if the problem continues.

NOTE

If these troubleshooting tables do not solve any problems that occur with the
SmartSwitch, contact Cabletron Systems. Refer to

Section 1.2

for details.

This manual is related to the following products: