beautypg.com

2 troubleshooting checklist, Troubleshooting checklist -5, Fault identification – Cabletron Systems 6H258-17 User Manual

Page 41: Section 4.2

background image

Troubleshooting Checklist

Troubleshooting

4-5

4.2

TROUBLESHOOTING CHECKLIST

If the SmartSwitch is not working properly, refer to

Table 4-2

for a checklist of possible problems,

causes, and recommended actions to resolve the problem.

Table 4-2

Fault Identification

Symptom

Possible Causes

All LEDs off.

1. Installation error - Remove the SmartSwitch and perform

installation in accordance with installation instructions. Check
connectors for dust or dirt and clean as necessary.

2. Power system fault - refer to

Table 4-3

.

Module stays in BOOT
state.

1. Device does not have an operable firmware image, and is

sending out BootP requests in an effort to locate a BootP server
on the network. Press the RESET button on the front panel to
attempt to use the firmware image in FLASH memory.

2. If the problem continues after pressing the RESET button, refer

to

Section B.1

for instructions on forcing a BootP image

download.

3. Contact Cabletron Systems if the problem continues.

Cannot access Local
Management.

1. Firmware image fault - refer to

Table 4-4

.

2. Management system fault - refer to

Table 4-5

.

Cannot contact device
through in-band
management.

1. Management system fault - refer to

Table 4-5

.

2. No link to device - verify all network connections between the

network management station and the SmartSwitch are valid and
operating.

User parameters
(IP address,
community names,
etc.) lost on reset or
power-up.

Device setup fault - refer to

Table 4-6

.

Device is not
forwarding traffic from
any port.

Device setup fault - refer to

Table 4-6

.