10

.

The electrical connections must

be done by a licensed electrician.

1 1 ■ Check leveiness of dryer by

piacing level on top of the dryer, first side to

side, then front to back. If dryer is rx)f level,

adjust the legs of the dryer up or down.

Dryer must be level to prevent noise and

poor drying performance.

Connecf exhaust duct to

exhaust hood and dryer. (See Exhaust

requirements. Panel B.)

• Use the straightest path possible to avoid

90° turns.

• Use duct tape to seal all joints in the

exhaust system.

• Use caulking compound to seal exterior

wall opening around exhaust hood.

13

■ Check that all parts you

removed from the parts packages are now

Installed In the dryer. If fhere is an extra part,
go back through the steps to see which step

was skipped.

i d

m

m Check to make sure you have all

the tools you started with.

15

Carefully slide dryer into its final

location. Check to be sure legs were

properly installed and dryer is level.

16

Read the Use and Care Guide to

fully understand your new dryer. Start the
dryer and allow it to complete a full heat

cycle (not the air cycle). After five minufes,

open dryer door. You should feel heaf inside
the dryer. If you do not feel heat, follow

instructions given on back cover, “If dryer

does nof operafe properly."

You have Just

finished Installing

your new Whirlpool dryer.

To get the most efficient use

form your new dryer, read your

Congrattilations!

Whirlpool Use and Care guide. Keep

Installation Instructions and Guide

close to dryer for easy reference.

The Instructions will make

reinstalling your Whirlpool

Dryer In another home

as easy as the first

InstallaHon.

Recessed and doset

installation instructions

The dryer may be Installed In a recessed area
or closet.

A WARNING

Fire Hazard

If the dryer Is Installed In

a

closet, the

dryer MUST be exhausted outside.
Failure to do so may result In a fire.

TO PREVENT LARGE AMOUNTS OF LINT AND

MOISTURE FROM ACCUMULATING, TO
MAINTAIN DRYING EFFICIENCY AND TO

PREVENT EXPOSURE TO POSSIBLE HEALTH

HAZARDS, THIS DRYER SHOULD BE EXHAUSTED

OUTDOORS.

The installation spacing is in inches and

centimeters and is minimum allowable.
Additional spacing should be considered for

ease of installation, servicing and compliance
with local codes and ordinances.
If cfoset door is Installed, the minimum

unobstructed air openings in top and bottom

is required. Louvered doors with equivalent air

openings are acceptabie. Closet instaliation

must be exhausted. Other installations must

use the minimum dimensions indicated.
Companion appliance spacing should be

considered.

For recessed, non-exhausted Installation,

Exhaust Deflector Kit, Part No. 3391278, Is
required.

Numbers

correspond

to steps.

Minimum instailation spacing

Closet installation must be exhausted.

closet door •

i

48 sq. in."

(309.7 sq cm)

14" (35.6 cm)

max.

T

i

>

24 sq. in.

(154.8 sq cm)

T

4"***_

(10.2 cm)

Side view

L

1

------------------------

3" (7.6 cm)

48 sq. in."

(309.7 sq cm)

t

Í

i

o

24 sq. in.”

(154.8 sq cm)

3" (7.6 cm)

Front view

* Additional clearances for wall, door and floor

moldings may be required.

** Opening is minimum for closet door. Louvered

door with equivalent air openings is

acceptable.

" Additional space is needed when external

exhaust elbow is used.

Panel C