![background image](/manuals/662994/3/background.png)
Installation Instructions
4.
Remove all tape and packaging material from the
outside and inside of the cabinet. See Figure 4.
5. Remove the front grill; take out the screws securing
the grill at the bottom and lift it free of cabinet.
6. Turn the fan by hand to make certain it moves freely.
7. Loosen thumb screws holding cutter grid and water
pan to “thumb tight.”
Utilities
WATER
ELECTRICITY
DRAIN
OBSERVE LOCAL CODES
Each installation is unique but will require:
1. A cold water inlet of V
a
” OD soft copper tubing and
a shut-off valve.
2. Either a gravity drain system or a sump pump to lift
the water to an existing drain.
3. An electrical branch circuit of 115 Volt, 60 Hz. 1
phase, with a 15 Amp delayed action fuse or circuit
breaker.
Locate unit
THIS UNIT MUST BE
INSTALLED IN AN
AREA PROTECTED FROM
THE ELEMENTS, SUCH
AS WIND, RAIN, WATER
SPRAY OR DRIP.
90“ F
70“ F
BEST
RANGE
2.
Area should be well ventilated with temperature
above 55° F and below 110°F. Best results are ob
tained between 70°F and 90°F.
3. Provision for electricity, water and drain connections
should be determined.
4. The unit may be closed in on the top and three sides,
but the front MUST BE unobstructed for air circula
tion and
proper
operation. Installation should be
such that the cabinet can be moved forward for ser
vicing, if necessary.
Level unit
1. After placing unit in position, check to make certain
the unit is level side to side and front to back.
2. Accurate leveling is essential for proper operation.
3. Unit should be shimmed so that it is solid as well
as level. The shims should be of hard permanent
type material such as masonite.
4. Compliance with National Sanitation Foundation
standards require that this type of product be sealed
to the floor at the bottom rail in order to prevent con
tamination from spills or the entrance of vermin.
Therefore, we recommend that when installing this
product you seal it to the floor in accordance with
those standards. A silicone-type sealer is recom
mended.
For the plumber
Connect to water
(Observe local codes)
1. Use V
a
” OD soft copper tubing for the cold water
supply.
2. Provide a convenient manual shut-off valve in the
water line.
3. Position the tubing so it can enter the access hole
located in the right-hand rear of the cabinet. The tub
ing shoud extend beyond the cabinet front when the
cabinet is pushed back into position. See Figure 5.
NOTE:
Always purge the water line before making the final con
nection to the inlet of the water valve to prevent possi
ble water valve malfunction.
1. Place unit so the front side will be completely
unobstructed to provide proper air flow.
After the cabinet is in place, bend the tubing to meet
the connection at the water valve. The garden hose
threaded compression fitting is found in the parts bag.
This joint provides a convenient disconnect for service.
Be sure the tubing is clear of compressor, to prevent
rattle.