CARING FOR YOUR DEHUMIDIFIER
Caring For Your Dehumidifier
Your dehumidifier is designed to serve you
year-round. It needs practically no attention.
However, you should check your dehumidifier
and inspect the coils annually.
You may call a service company to perform
this annual checkup or you can do it yourself.
Cost of annual inspection is the owner’s
responsibility.
OR
If you are familiar with electrical appliances
and their functions, listed below are instruc
tions which would allow you to do the inspec
tion and maintenance yourself.
^WARNING
Electrical Shock and
Personal Injury Hazard
• Disconnect power supply cord from
receptacle before performing any
maintenance.
• Be careful when cleaning the coils. Fins
are sharp.
Failure to follow the above precautions
could result in electrical shock or personal
injury.
Performing annual maintenance
1. Disconnect dehumidifier from power
supply.
2. Remove the front grille.
•Remove the two screws at bottom-front
of grille.
•Drop grille down and pull It out.
3. Remove the socket-head screws on each
side of the cabinet.
Socket-head screws
4. Remove the top flange screws.
Top flange screws
continued on next page