How to sanitize the storage tank
You will need to order Tank Sanitizing Kit, Part No.
4373527. You will also need household bleach and
a measuring spoon.
1. Turn off saddle valve in water line. Open faucet
and drain storage tank. There will be no water dripping
when tank is empty.
2
.
Turn off faucet. Push in grey connector to disconnect
yellow tubing from system. Connect yellow tubing to push
in connector on side of sanitizing kit.
3
.
Disconnect orange tubing from filtration assembly.
Connect orange tubing to tank sanitizing kit’s other
push-in connector.
4
.
Put
1/2
teaspoon of bleach into tank sanitizing kit.
5
.
Turn on saddle valve in water line. Allow storage
tank to fill for about 3 minutes. Turn off saddle valve in
water line and the valve at the top of storage tank.
6
.
Wait 15 minutes. Disconnect tank sanitizing kit
from storage tank. Disconnect the orange tubing from
the tank sanitizing kit.
7
.
Reconnect orange tubing to filtration assembly.
Reconnect yellow tubing to filtration system.
8
.
Turn on saddle valve in water line and the valve
at top of storage tank. Open faucet and drain tank.
There will be water dripping when the tank is empty.
9
.
Allow tank to refill. Wait about 6 hours. Drain tank
again and allow it to refill. If water has a taste, drain
tank and allow it to refill again.
Preparation for long periods of non-use
Follow these instructions if RO system will not be used
for more than 30 days.
1. Turn off saddle valve in water line. Open faucet to
drain tank. There will be no water dripping when
tank is completely empty. Wait five minutes for filtration
assembly to depressurize.
2
,
Remove all cartridges. Place cartridges upside-
down in sink or bucket to drain water from cartridges.
Place cartridges in a plastic bag and seal tightly. Place
bag with cartridges in refrigerator.
DO NOT allow
cartridges to freeze.
Using RO system after long periods
of non-use
1
. Follow instructions for replacing cartridges.
2
.
Sanitize storage tank.
3
.
Sanitize RO System.
4
.
Follow “Flush System" instructions.
Call 1-800-253-1301 to order.
If You Need Assistance...
The Whirlpool Consumer Assistance Center will answer any questions about
operating or maintaining your RO water filtration system not covered in
the Installation Instructions/Use and Care Guide. The Whirlpool Consumer
Assistance Center is open 24 hours a day, 7 days a week. Just dial
1-800-253-1301 -the call is free.
When you call, you will need the RO water filtration system model number
and serial number. Both numbers can be found labeled on the top right side
of the filtration assembly.
How To Arrange For Service...
In the event that your Whirlpool appliance should ever need service, call the
dealer from whom you purchased the appliance or a Whirlpool-authorized
service company. A Whirlpool-authorized service company is listed in the
Yellow Pages of your telephone directory under “Appliances-Major-Service
or Repair." You can also obtain the service company's name and telephone
number by dialing, free within the continental United States, the Whirlpool
Consumer Assistance Center telephone number, 1-800-253-1301. A special
operator will tell you the name and number of your nearest Whirlpool-
authorized service company.
Maintain the quality built into your Whirlpool appliance - call a Whirlpool-
authorized service company.
Ifi
Replacement Parts & Accessories
Replacement Cartridge Kit
Kil includes Sediment (S), GAC Carbon (GAC) and
Carbon Block (CB) Cartridges. Cartridges can also
be ordered individually. TPCM Membrane Cartridge
(RO) needs replacing only once every two years,
when indicator disk light turns yellow.
4373575
TFCM Membrane Cartridge (RO)
4373501
Sediment Cartridge (S)
4373502
GAC Carbon Cartridge (GAC)
4373503
Carbon Block Cartridge (CB)
4373504
SFC Flow Control (Red Tubing)
4373508
Filtration Assembly Cover
4373509
Storage Tank
4373511
Air Gap Faucet
4373522
Refrigerator Hook-up Kit
4373505
Additional Parts
Needed For Multiple
Connections:
%" Tubing •
4319151
“T" Connector with Push-in Ends
4319152
% Reiection Monitor
4373512
Flow Sensor
4373513
LED Faucet Base Assembly
4373514
Installation Instructions
4373500B
Installation Kit
4373518
Tubing Kit
4373519
Vi"
Green Tubing 4'
4373516
Spare “O" Ring Kit
4374515
Drain Saddle Assembly
4373520
Saddle Valve, Self-tapping
4373521
Basement Installation Kit
4373517
Booster Pump
4373525
Tank Sanitizing Kit
4373527
% Connector with Push-in Ends
4373546
Ya “T" Connector with Push-in Ends
4373547
Ya-'A Male Connector with Push-in Ends
4373548
Y
b
-V4 Reducing Connector with Push-in Ends
4373549
'U
Elbow Connector with Push-in Ends
4373556
Ya Elbow Connector with Push-in Ends
4373557
Whirlp
/
^^CO«PO«AriON
MODEL IV REVERSE OSMOSIS DRINKING WATER TREATMENT UNIT
MODEL NO. WSR413YW
REPLACEMENT CARTRIDGE: WHIRLPOOL RO ESP# 4373501
WHIRLPOOL GAC ESP# 4373503
WHIRLPOOL S ESP# 4373502
WHIRLPOOL CB PSP# 437504
SERVICE PLOW RATE - 0.6 gpm (2.28 Ipm)
MAX. OPERATING PRESSURE -100 psig (862 kPa)
MIN. OPERATING PRESSURE - 40 psig (345 kPa)
MAX. OPERATING TEMPERATURE 100°E (38°C)
NOTICE: DO NOT USE WHERE WATER IS MICROBIOLOGICALLY UNSAPE OR WITH WATER OP UNKNOWN QUALITY.
THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSP STANDARD 58 POR TOTAL DISSOLVED SOLIDS, ARSENIC,
BARIUM, CADMIUM, CHROMIUM, NITRATE, LEAD. MERCURY, RADIUM, AND SELENIUM REDUCTION. SEE PERPORMANCE
DATA SHEET POR PERMISSIBLE CLAIMS.
NITRATE REDUCTION MODELS ("NITRATE”) ARE ACCEPTABLE POR TREATMENT OP INPLUENT CONCENTRATIONS UP
TO 30 mg/L; ADDITIONAL TREATMENT SHALL BE REQUIRED POR HIGHER INPLUENT LEVELS.
THIS SYSTEM IS NOT CERTIPIED POR NITRATE REDUCTION IN WATER SUPPLIES WITH A PRESSURE
OP LESS THAN40PSI.
WHIRLPOOL CORPORATION, BENTON HARBOR, Ml, USA.
(NSF.
IT IS ESSENTIAL THAT OPERATIONAL, MAINTENANCE AND PILTER REPLACEMENT REQUIREMENTS
BE CARRIED OUT POR THE PRODUCT TO PERPORM AS ADVERTISED.--