Troubleshooting, Roubleshooting, Maintenance 4.3. troubleshooting – CMA Dishmachines GL-X User Manual
Page 13
Maintenance
4.3. Troubleshooting
PROBLEM LIKELY
CAUSE
SOLUTION
Power off at circuit breaker
Reset circuit breaker
Defective power switch
Replace power switch
P/N: 00433.10
Machine inoperative
Defective timer assembly motor
Replace timer assembly motor
P/N: 00501.00
Door is open
Close door
Control drawer is pulled out
Secure control drawer
Defective reed (door) switch
Replace reed (door) switch
P/N: 00557.55
Defective timer assembly
(Cam 7)
Replace timer assembly*
P/N: 00408.80
Defective pump motor contactor
Replace contactor
P/N: 00404.82
Pump Motor inoperative
Defective pump motor
Replace pump motor
P/N: 00201.00
Defective reed (door) switch
Replace reed (door) switch
P/N: 00557.55
Defective pump motor contactor
Replace contactor
P/N: 00404.82
Pump Motor runs with door
open
Delime switch is on
Turn off delime switch
Motor runs continuously
Delime switch is on
Turn off delime switch
Defective thermostat on heater
Replace heater
P/N: 04109.10
Defective heater relay
Replace heater relay
P/N: 00631.00
Defective timer assembly
(Cam 8)
Replace timer assembly *
P/N: 00408.80
Defective heater
Replace heater
P/N: 04109.10
Defective float switch
Replace float switch
P/N: 13463.00
Fill wash tank completely
Sustainer Heater
Float switch not actuated
Level machine
Defective thermostat on heater
Replace heater
P/N: 04109.10
Defective timer assembly
(Cam 8)
Replace timer assembly *
P/N: 00408.80
Sustainer Heater
Defective heater relay
Replace heater relay
P/N: 00631.00
*The timer assembly motor (
P/N: 00501.00
) or micro switches (
P/N: 00411.00
) can be replaced
independently if that is the only component that has failed.
MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01 –08/04/05 PAGE
12