Symptom, Possible causes, Possible sources – CAMCORP Blower Package with Roots Blower User Manual
Page 11

CAMCORP, Inc.
Phone: 913-831-0740 ~ Fax: 913-831-9271
www.camcorpinc.com
Symptom
Leaking Oil
Chronic Fuse Blowing or
Circuit Breaking
Overheating
Possible Causes
Failed Oil Seals
End Cover Seams Not Tight
Oil Foaming
Excessive Motor Amperage
Underrated Fuses
Premature Heater Strip
Actuation
Excessive Pressure Ratio
Insufficient Rotor Speed
10
Possible Sources
Foreign Material in Seal Bores
Faulty Installation
Non-spec Oil
Contaminated Oil
Overheated Rotor Shafts
Bolts Loose
Gaskets Torn
Non-spec Oil
Oil Cavities Overfilled
Excessive Pressure Ratio
Excessive Pump Speed
Line Voltage Drop
Air Density Increase
Loose Electrical Connections
Foreign Material in Air Box
Unusually High Ambient
Temperature
Underrated Heater Strips
Clogged Filter Element
Collapsed Inlet Hose
Clogged Dust Vent Filter
Undersized Dust Vent Filter
Clogged Diffusion Pads
Faulty Check Plate
Improperly Installed Check
Plate
Wrong Sheave Set
Wrong Motor Speed
Slipping Belts