Symptom
Poor Performance
Possible Causes
Belt Flutter
Restricted Inlet
Down Stream Restriction
Erroneous Pressure or
Vacuum Indication
Air Leakage
Insufficient Rotor Speed
Excessive Rotor Clearances
Change in Conveyed
Material
9
Possible Sources
Insufficient Static Tension
Sheave Misalignment
Sever Torsional Vibration
Clogged Filter Element
Collapsed Inlet Hose
Clogged Dust Filter
Undersized Dust Filter
Faulty Check Plate
Improperly Installed Check
Plate
Loose Gauge Connection
Gauge Movement Damaged
Gauge Inaccurately Calibrated
Improper Relief Valve Setting
Blown Gaskets
Loose Piping Joints
Wrong Sheave Set
Wrong Motor Speed
Slipping Belts
Abrasive Wear of Rotor
Surfaces
Rotor “Lag” Timed
Material More Difficult to
Fluidize
Material of Higher Density
Moisture Content of Material
Too High