Section 7 – routine maintenance – CAMCORP Cartridge Collector User Manual
Page 55
![background image](/manuals/661920/55/background.png)
CAMCORP, INC.
Phone: 913-831-0740 Fax: 913-831-9271
www.camcorpinc.com
Section 7 – Routine Maintenance
Inspection
Frequency will vary as widely as there are operating conditions. In
general proceed as follows:
Daily – Check unit differential pressure.
Weekly – Check pulse timer board and solenoid valves for function.
This usually is only listening to check uniform time in intervals between
blasts.
Monthly – Lubricate fan, rotary valve and screw conveyor. Check seals
on latter two for dust loss.
Quarterly – On Top Access Units, check for dust accumulation in clean
air plenum.
Repairs
Filter cartridges – Generally replacement, although some applications
can be laundered.
Solenoid Valves – Repair kits are available if a valve is stuck open or
fails to operate.
Diaphragm Valves – Repair kits are available if a valve is stuck open or
fails to operate due to a ruptured diaphragm.
Rotary Valves – Usually a matter of periodic seal and blade
replacement. More detailed information is supplied with the valve.
Screw Conveyors – Periodic replacement of “V” belts and shaft seals.
Inspect hanger bearings during filter bag change. Failure will be
detected by the squeal.
Fans – “V” belt tension and replacement of bearings if running rough.
Make sure rotor balance is maintained.
7-1