Corporation
4
Previous
Next
4-12
Features
■ Field Selectable from 2 to
10 Outputs
■ Completely Solid-state
Timing and Switching
Logic
■ 300% Overrated Solid-
state Switch
■ Pressure Switch Control
Option On Board
■ 12 to 24 Volts D.C. Input
Voltage
■ Adjustable "On" and "Off"
Times
■ High Quality Locking
Bushing Potentiometers
for Timing Adjustment
■ Very Low Power
Consumption
■ RTV Protective Coating
for Corrosion and
Moisture Resistance
■ LEDs Show
Compartment Being
Cleaned
■ Metal Chassis Provided
For Mounting Directly
Into NEMA-4 Enclosure
Operating Logic: The control can function in 2
modes:
Continuous Mode: The pressure switch terminals
are shorted. Upon application of output voltage,
the control activates output #1 after the preset off
time. It will continue to activate outputs sequen-
tially until input voltage is removed.
On Demand Mode: The pressure switch termi-
nals are connected to an isolated set of contacts of
a differential pressure switch. The control will acti-
vate the outputs sequentially whenever the pres-
sure switch contacts are closed. When the pressure
switch contacts open, the output sequencing stops.
Re-closing of the contacts will cause the control to
resume activating the outputs.
Program wire allows the user to select the maxi-
mum number of outputs to be activated.
DC Input, Pulse
Cleaning of bag
House Dust
Collectors Model
DNC-T2010-ADC
Dust Collector
Controls
No. of
Outputs
2 - 10
12 - 24 VDC
1.5 - 60
DNC-T2010-ADC
Input Voltage
Off Time
(In Seconds)
Part Number
Time Setting Ranges
On Time: Adjustable from 20 to 200 millisec-
onds
Off Time: Adjustable from 1.5 to 60 seconds
Repeatability: ±3% over temperature & voltage
ranges
Input
Operating Voltage: 10.0 to 29.0 VDC
(Unfiltered supply voltage must be full-wave
rectified.)
Power Consumption Voltage During Off
Time: 1.5 Watts @ 12 VDC, 4.2 Watts @ 24
VDC
Output
Type: Solid-state switch
Load Per Output: 3 Amp maximum @ 1.5 V
less than input voltage
Protection
Transient Input Voltage: Metal oxide varistor
plus large filter capacity
Transient Output Voltage: Solid-state switch
rated at 10 Amps. - 60 Volts fly-back diode pro-
tected
Short Circuit Protection: 3 Amp fuse for circuit,
Reverse polarity protected
Environmental
Operating Temperature: -40°F to 150°F
(-40°C to 60°C)
Storage Temperature: -40°F to 185°F
(-40°C to 85°C)
Specifications