R2-Series User’s Manual
MKTF - 212
The amount of permeate water recovered for us
and % rejection, use the following formula
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100
% Rejection = (Feed TDS
NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS
SYSTEM REQUIREMENTS
PLUMBING
The membranes and high pressure pumps used on R
continuous flow of water with a minimum
FEED WATER CONNECTION
1. Locate the 1” FNPT Sole
(Figure 1A, Page 13)
2.
Attach the inlet piping to the 1
PERMEATE (PRODUCT WATER) CONNECTION
Locate the 1” or 3/4” connection (d
Ensure that the permeate water can flow freely
irreversible damage to the membrane elements.
be run to the holding tank with PVC fittings, or other FDA approved materials
being used does not leach into the permeate water.
CAUTION: THE PH OF THE REVERSE O
BE 1-2 PH UNITS LOWER THAN THE FEED WATER PH.
A LOW PH CAN
PLUMBING MATERIALS SUCH AS COPPER PIPING.
CONCENTRATE (WASTE WATER)
6
Series User’s Manual
water recovered for use is expressed as a percentage. To calculate % recovery
following formulas:
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100
Example:
25% = (1.04/4.04) x 100
% Rejection = (Feed TDS – Product TDS)/(Feed TDS) x 100
Example:
99.2% = [(10,000-80)/10,000] x 100
NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS.
SYSTEM REQUIREMENTS AND OPERATION GUIDELINES
gh pressure pumps used on R2-Series Reverse Osmosis Sy
us flow of water with a minimum feed pressure of 45 psi, not to exceed 85
FEED WATER CONNECTION
” FNPT Solenoid Valve feed water inlet.
tach the inlet piping to the 1” FNPT Solenoid Valve feed water inlet.
PERMEATE (PRODUCT WATER) CONNECTION
1” or 3/4” connection (depending on the unit) labeled permeate and attach to
sure that the permeate water can flow freely with no backpressure. Backpressure can cause
damage to the membrane elements. The 1” or 3/4” (depending on the unit)
with PVC fittings, or other FDA approved materials. This is so
into the permeate water.
H OF THE REVERSE OSMOSIS PERMEATE WATER WILL TYPICA
LOWER THAN THE FEED WATER PH.
A LOW PH CAN
PLUMBING MATERIALS SUCH AS COPPER PIPING.
CONCENTRATE (WASTE WATER) CONNECTION
11/13/12
e is expressed as a percentage. To calculate % recovery
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100
x 100
OPERATION GUIDELINES
Reverse Osmosis Systems require a
exceed 85°F.
labeled permeate and attach to the storage tank.
Backpressure can cause
epending on the unit) permeate line can
This is so that the material
SMOSIS PERMEATE WATER WILL TYPICALLY
LOWER THAN THE FEED WATER PH.
A LOW PH CAN DAMAGE CERTAIN