5.3 Manual Setting of Memory Switch
Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table. (The
white-on-black characters
are factory setting.)
Switch No.
Setting
0 (OFF)
1 (ON)
Memory SW1-1
Power ON Info
Send
Not send
Memory SW1-2
Buffer Size
4k bytes
45 bytes
Memory SW1-3
Busy Condition
Full/Err
Full
Memory SW1-4
Receive Error
Print “?”
Invalid
Memory SW1-5
CR Mode
Ignored
LF
Memory SW1-6
Reserved
Fixed
−
Memory SW1-7
DSR Signal
Invalid
Valid
Memory SW1-8
Reserved
Fixed
−
Memory SW2-1
Reserved
−
Fixed
Memory SW2-2
Reserved
Fixed
−
Memory SW2-3
Spool print
Invalid
Valid
Memory SW2-4
Full col print
LineFeed
WaitData
Memory SW2-5
Resume aft PE
Print next line
Print top
Memory SW2-6
Reserved
−
Fixed
Memory SW2-7
Reserved
Fixed
−
Memory SW2-8
PNE sensor
Valid
Invalid
Memory SW3-1
Reserved
Fixed
−
Memory SW3-2
Reserved
Fixed
−
Memory SW3-3
Parallel 31 Pin
Valid
Invalid
Memory SW3-4
Reserved
Fixed
−
Memory SW3-5
Reserved
Fixed
−
Memory SW3-6
Reserved
Fixed
−
Memory SW3-7
CBM-270 mode
Invalid
Valid
Memory SW3-8
Resum Open Err
Close
Command