Antari B-200 User Manual
Page 9
8
DMX Connector Pin Assignment
5 pin XLR connector for DMX connection. Diagram below indicate pin assignment
information
Pin
Function
1
Ground
2
Data-
3
Data+
Using DMX to control the B-200:
Set the desired DMX channel using the dip switches at the back of the machine.
Connect the bubble machine to the DMX chain using the input and output sockets.
NOTE: The machine uses only one DMX channel. This channel does not control bubble
volume, it only controls on & off functions.
DMX protocol
DMX value
Feature
0 -128
OFF
129-255
ON
Addressing
Each device occupies 1 channel. To ensure that the control signals are properly directed
to each device, the device requires adressing. This is to be done for every single device by
changing the DIP switches as set out in the table below.
The starting address is defined as the first channel from which the device will respond to
the controller. Please make sure you don’t have any overlapping channels in order to
control each device correctly and independently from any other device on the DMX data
link. If two, three or more devices are addressed similarly, they will work similarly.
Occupation of the DIP-switches: