beautypg.com

Remote control operation only for sw-250 model – Antari SW-250 User Manual

Page 7

background image

7

There’s a small button “AIR VOLUME” located at rear of the machine used for adjusting the fan output volume.

In general, when the fan output is increased the snow flakes produced are smaller. In contrast, when the fan

output is decreased, bigger snow flakes will be produced. However, the snow output volume will not be

affected.

Note: When the machine senses no fluid in the fluid pipe, LCD screen will blink and show “No Fluid”.

Meanwhile, the machine is locked and not able to output for preventing machine from further ineffective work.

Check immediately if the snow fluid in tank has been run out. To unlock the LCD screen, press

Stop for

2 seconds and the machine will try to pump again the snow fluid. When the fluid pipe is full of snow fluid then

the machine will be functional again.

REMOTE CONTROL OPERATION

ONLY FOR SW-250 MODEL

W-1: The wireless remote control W-1 consists of a transmitter equipped with two buttons for output on and off,

and a receiver pre-attached to SW-250.

* Transmitter

With the transmitter it is possible to output via radio over a distance of up to 50 meters. The transmitter is

compatible to any receiver of SW-250 and can control an unlimited number of machines in parallel. Press the

button “A”, to ouput. As control, the LED on the transmitter is lit. To stop the output, press the button “B”.

* Receiver