STEP 2-SYSTEM CONNECTIONS HOOKUP STEPS
A). Make all your slave connections BEFORE you apply power to the unit. The master unit will power itself and the 2
slaves. To connect power to your new ADVANTAGE DKS II system, run two wires from near an outlet out to the master
unit. Connect the 2 wires to the white wires on the master board. On the other end, connect the two wires to the
provided transformer (don’t worry about polarity).
(B). Connect the device(s) to be controlled to the appropriate terminal(s). (Relay Connections)
(C). Double check your connections. When you are sure you have the unit hooked up correctly, plug the
transformer into an outlet. If this is the first time power up, the unit will perform some self diagnostics and setup the
memory. The unit will flash the LED’s several times while it is performing the first time setup. If everything goes O.K.,
you will hear a GOOD BEEP from the unit. If the unit does not perform as above, quickly turn off power to the unit and
contact American Access Systems.
NOTE: THE UNIT WILL ONLY PERFORM THE SELF DIAGNOSTICS AND MEMORY SETUP THE FIRST TIME IT IS POWERED UP.
FROM THERE ON OUT THE UNIT WILL SOUND A GOOD BEEP IMMEDIATELY AFTER POWER IS APPLIED.
CONNECTING GATE CONTROL WIRES
Run your gate control wires to the master unit and make your connections on the communications and relays board,
where it says relay A, (If you are operating two gates etc. the other connections will be made to relay B). Be careful
that when you close the unit that pressure is not put on the circuit board, and that none of your wires are hitting the
reset button.
STEP 2 -SYSTEM CONNECTIONS
HOOKUP STEPS
COMMUNICATIONS
&
RELAYS
PRINTER POWER HOOKUP
( 2 PIN TERMINAL )
ACCESS CONTROL UNIT
(ACU)