Group 200 (deleting codes), Group 300 (miscellaneous) – American Access Systems Advantage DKSII - Regular - 24-1000i User Manual
Page 12

Page 12 American Access Systems / Security Brands, Inc.
GROUP 200 (DELETING CODES)
“200”
SubMode 200 (DELETE CODES)
To delete any code from memory, with the exception of the MASTER CODE, enter the 5 digit “MASTER CODE”
followed by submode “200” and then the code to be deleted.
(MASTER CODE) + 200 + (CODE TO BE DELETED) + (NEXT CODE TO BE DELETED) etc...(# to exit)
You may continue deleting codes in a successive manner. When you are finished press # to exit. Should you make
an entry error, simply press the * key and reenter the correct data. Should you receive an ERROR after you enter a
code to be deleted, the code was not found in memory and the unit will wait for you to enter another code to be
deleted. The unit will respond with a GOODBEEP after each successful deletion.
GROUP 300 (MISCELLANEOUS)
“300”
SubMode 300 (SET RELAY A OUTPUT TIME)
DESCRIPTION: The output time of relay A can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.
To set the output time of relay A in seconds enter the 5 digit “MASTER CODE” followed by submode “300” and then a 2
digit number corresponding to the number of seconds.
(MASTER CODE) + 300 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been
accepted. If you enter 00 for seconds the output time is set to 1/2 second. Should you make an entry error, simply
press the * key and reenter the correct data.
“301”
SubMode 301 (SET RELAY B OUTPUT TIME)
DESCRIPTION: The output time of relay B can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.
To set the output time of relay B in seconds enter the 5 digit “MASTER CODE” followed by submode “301” and then a 2
digit number corresponding to the number of seconds.
(MASTER CODE) + 301 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been
accepted. If you enter 00 for seconds the output time is set 1/2 second. Should you make an entry error, simply press
the * key and reenter the correct data.
“302”
SubMode 302 (SET CLOCK TIME)
To set the clock time enter the 5 digit “MASTER CODE” followed by submode “302” then the “HOURS” and “MINUTES” of
the day in military format.
(MASTER CODE) + 302 + (HOURS) + (MINUTES)
Example:
8:23 a.m. = “08” + “23”
5:00 p.m. = “17” + “00”
The unit will respond with a GOODBEEP and exit from the program mode after the TIME has been accepted into the