Group 100 (programming codes) – American Access Systems Advantage DKSII - Regular - 24-1000i User Manual
Page 10
Page 10 American Access Systems / Security Brands, Inc.
GROUP 100 (PROGRAMMING CODES)
“100”
SUBMODE 100 (PROGRAM ACCESS CODES)
HELPFUL HINT: REMEMBER, IF YOU DO NOT WANT TO COME UP WITH CODES YOURSELF THIS UNIT CONTAINS AN RCG
FEATURE (RANDOM CODE GENERATION) SEE SUBMODE 304 AND 305. KEEP IN MIND YOUR NEW CODES MUST BE LESS
THAN 65535 AND NOT ALREADY IN USE BY THE SYSTEM. PAGE 18 IN THIS MANUAL IS AN ACCESS CODE LOG SHEET
WHICH MAY BE PHOTO-COPIED FOR KEEPING TRACK OF ALL CODES IN THE SYSTEM.
DESCRIPTION: Access codes are codes given out to end users to gain access onto the property. The number of
access codes you may program into the unit is reflected in the corresponding model number of the unit. Each time
an access code is entered into the system, the code, date, and time are logged into the history buffer. If you are
interfacing a slave keypad(s) to the system and the “SPLIT RELAY” feature (see submode 307) is enabled then all
access codes entered from the master and slave 1 will activate relay A and all access codes entered from slave 2
will activate relay B. From the factory all access codes will activate relay A. Access codes are not accessible while in
the SLEEP MODE (see submode 103).
To program in new access codes enter the 5 digit “MASTER CODE” followed by submode “100” then enter each 5 digit
“ACCESS CODE” you wish to program into the unit.
(MASTER CODE) + 100 + (ACCESS CODE) + (ACCESS CODE) etc...(# to exit)
You may continue entering access codes until either the memory is filled or the # is pressed. Should you make an
entry error, simply press the * key and reenter the correct data. You may select any 5 digit code less than 6 5 5 3
5 that is not already in use. Should you receive an ERROR after you enter a new access code, you must select a
different one as it is already in use by the system. The unit will respond with a GOODBEEP after acceptance of each
new access code. You will automatically be exited from the program mode when the access code memory is filled.
When memory is completely filled you will not be able to enter this SubMode and will receive an ERROR if entry is
attempted.
“101”
SUBMODE 101 (PROGRAM MANAGERS CODES)
DESCRIPTION: Managers codes are given out to individuals to gain access onto the property regardless of the SLEEP
STATE (see submode 103) of the unit. Each time a managers code is entered into the system, the manager code,
date, and time are logged into the history buffer. A maximum of 15 managers codes for the 24-100 & 24-500 and 30
manager codes for the 24-1000 & 24-2000 may be programmed into the unit. If you are interfacing a slave keypad(s)
to the system and the “SPLIT RELAY” feature (see submode 307) is enabled, all managers codes entered from the
master and slave 1 will activate relay A and all managers codes entered from slave 2 will activate relay B. From the
factory all managers codes will activate relay A.
To program in managers codes enter the 5 digit “MASTER CODE” followed by submode “101” then each 5 digit “MAN-
AGERS CODE” you wish to program into the unit.
(MASTER CODE) + 101 + (MANAGERS CODE) + (MANAGERS CODE) etc...(# to exit)
You may continue entering managers codes until the unit holds a total of 15 managers codes for a 24-100 & 24-500,
30 manager codes for the 24-1000 & 24-2000 or the # is pressed. Should you make an entry error, simply press the
* key and reenter the correct data. You may select any 5 digit code less than 6 5 5 3 5 that is not already in use.
Should you receive an ERROR after you enter a new managers code, you must select another as it is already in use
by the system. The unit will respond with a GOODBEEP after acceptance of each new managers code. You will
automatically be exited from the program mode when the MANAGER MEMORY is filled. If the MANAGER MEMORY is
full you will not be able to enter this SubMode and will receive an ERROR if entry is attempted.
“102”
SUBMODE 102 (PROGRAM MASTER CODE)
DESCRIPTION: The master code is used to gain access to the program mode. The factory default master code is
01251. The master code is only accepted into the system from the master unit. The master code cannot be deleted
from memory, only changed. The master code is not accessible while in the sleep mode (see submode 103).
To program in a new master code enter the PRESENT 5 digit “MASTER CODE” followed by submode “102” then the
“NEW MASTER CODE” you wish to program into the unit.
(PRESENT MASTER CODE) + 102 + (NEW MASTER CODE
The unit will respond with a GOODBEEP after acceptance of the new master code and you will automatically be
exited from the program mode. Should you make an entry error, simply press the * key and reenter the correct data.
You may select any 5 digit code less than 6 5 5 3 5 that is not already in use. Should you receive an ERROR after you
enter a new master code, you must select a different one as it is already in use by the system.