Jaclo ½" thermostatic valve - J-THVC12 User Manual
Page 6

JACLO.COM
| PG 6
THERMOSTATIC WALL VALVE
DIAL POINTER, TRIM & HANDLE INSTALLATION
1
›
Rotate the spindle until the temperature of water stabilizes at 100°F.
2
›
Push the dial pointer (8) into sleeve (9), with the arrow up in the 12 o’clock position (Fig.6). Install dial assembly (6) over
the spindle until it bottoms (without rotating it), aligning the 100°F marking to the arrow of the insert (8).
3
›
Place the self adhesive backed foam strip (24) onto the inside surface of the traditional front plate (18) only.
Position the opening in the down position to prevent water infiltration. Slide front plate (18) or (19) gently over sleeve (9)
until firmly seated against wall. Place a bead of silicone around the outer edge of front plate to secure it in position and
fill any gaps.
4
›
Install handle and secure with setscrew (see Fig.7). Do not overtighten.
NOTE: If valve is installed too deep, order extension kit DUAL THERM-EXT to extend handle height & sleeve by 1". (See Page 2).
- Dual lever therm - T6592- Dual lever ½" thermostatic valve with integral volume control - T6570- Contemporary thumb and lever - T6572- ½" therm extension kit - J-THVC12-EXT Cross and lever dual therm - T6534- Dual lever therm valve - T6536- Dual mini lever therm valve - T6000- Contemporary cross and lever - T6530- Contemporary dual lever - T6532-