Roubleshooting – Intertape Polymer Group (IPG) TWA 1000-M User Manual
Page 20

TWA 1000-M (U9701)
UDM 9701
20
T
ROUBLESHOOTING
The TWA 1000-M Water Activated Table Top Dispensers are fabricated with high quality components
that provide trouble-free operation for a long period of time. However, should a problem occur, we
recommend that you consult the following table. If the problem you encounter is not discussed in this
table, call Interpack Technical Support. (see page 2 of this document).
Trouble
Possible Causes
Solutions
Tape is jamming
Debris in the tape path
Adhesive build up
Pressure plate missing or installed
incorrectly
Too much weight on the moistening
brush
Cutter blade not adjusted properly
Side guides set incorrectly
Clean Tape Path (see preventive
maintenance)
Clean tape path, moistening
brush and brush pot
Install pressure plate (see tape
threading)
Reduce brush weight setting (see
set up)
Re-adjust cutter blade (see
preventive maintenance)
Loosen or tighten as necessary
(see set up)
Tape does not cut
cleanly.
Debris in the cutter blade
Cutter blade not adjusted properly
Blade dull
Weak Return Spring
Clean cutter blade (see
preventive maintenance)
Re-adjust cutter blade (see
preventive maintenance)
Replace cutter blade (see
preventive maintenance)
Replace Return Spring
Tape is too dry
Dirty brush
Water level in brush pot too low
Clean moistening brush (see
preventive maintenance)
Adjust water level in brush pot
(see set up)
Tape is too wet
Water level in brush pot too high
Adjust water level in brush pot
(see set up)