Rocedures – Intertape Polymer Group (IPG) TWA 1000-M User Manual
Page 18

TWA 1000-M (U9701)
UDM 9701
18
S
ET
-U
P
P
ROCEDURES
Adjusting The Brush Pot Water Level
If the tape is too wet as it is processed, you may
need to Lower the water level in the brush pot
If the tape is too dry as it processed, you may
need Raise water level in the brush pot.
To do so:
1. Lift off the water bottle and set aside
2. Using a Phillips screwdriver, rotate the
screw counter clockwise to Raise the
water level or clockwise to Lower the
water level
Figure 7-11
Adjusting The Brush Weight
The function of the brush weight is to provide
enough downward pressure on the tape as it
travels over the moistening brush so that the
adhesive is properly activated. The brush
weight is adjusted at the factory and should not
require further adjustment. However, should
you process lightweight non-reinforced tapes,
you may wish to reduce the weight on the
moistening brush.
1. Loosen the locking nut
2. Slide the weight forward to increase brush
weight
3. Slide the weight to the rear to decrease the
brush weight
Figure 7-12
Water Level
Adjustment Screw
Brush Weight