4 | compressor assembly – GEA Bock HG34e A User Manual
Page 13
D
GB
F
E
13
96191-11.2014-DGbFE
4 | Compressor assembly
Fig. 17
Fig. 18
Valve spindle seal
Release
Tighten
4.7 Operating the shut-off valves
Before opening or closing the shut-off valve, release the adjustable valve spindle seal by approx.
¼ of a turn counter-clockwise.
After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.
Pipe connection
Pipe connection
4.8 Operating mode of the lockable service connections
Fig. 19
Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.
Fig. 20
Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise.
—> Service connection opened / shut-off valve opened.
Service connec-
tion closed
Connection
blocked
Spindle
Service connec-
tion opened
Spindle
Connection
open
Compressor
Compressor